文献速递乳腺癌放疗

乳腺癌放疗中腋窝淋巴结勾画变异对剂量学的影响:AIRO多中心研究

The dosimetric impact of axillary nodes contouring variability in breast cancer radiotherapy: An AIRO multi-institutional study.
PubMed 文献 · Radiother Oncol · 2022-01-13

18家放疗中心对3例乳腺癌患者的腋窝淋巴结(L2、L3、L4)进行勾画和计划设计,比较各中心单中心靶区与专家共识金标准靶区的剂量差异。结果显示金标准CTV的D98和D95显著低于单中心CTV,L4水平覆盖概率最低,IMRT广泛使用但CTV-to-PTV外扩未能补偿勾画差异。

要点

  • 金标准CTV的D98和D95显著低于单中心CTV,最大剂量无显著差异且均低于110%。
  • 平均剂量≥99%的满足率:单中心CTV为84%,金标准CTV为50%。
  • 金标准CTV的V95%高于90%的计划不足一半,L4水平被95%等剂量线覆盖的概率最低。

核心结论

  • 总体而言,金标准CTV的覆盖更差,尤其是L4水平。
  • IMRT被广泛使用,但CTV-to-PTV外扩未能补偿勾画问题。
  • 结果强调需要对勾画进行培训和标准化。

研究设计与样本

  • 18家放疗中心参与,对3例乳腺癌患者(P1、P2、P3)的腋窝淋巴结(L2、L3、L4)进行勾画和计划设计。
  • 各中心基于自身临床靶区(SC-CTV)应用本机构外扩生成单中心计划靶区(SC-PTV)并制定计划。
  • 金标准CTV(GS-CTVs)由乳腺癌专家共识制定并用STAPLE算法验证。
  • 将各中心所用相同外扩应用于GS-CTV生成GS-PTV,替换SC-PTV后重新计算剂量。
  • 数据集导入MIM v6.1.7软件提取剂量体积直方图(DVHs)并分析差异。

主要发现

  • 17/18家中心使用调强放疗(IMRT)。
  • CTV到PTV外扩范围为0至10 mm(中位5 mm)。
  • 95%等剂量线对GS-CTV的覆盖与GS-PTV外扩宽度之间未观察到相关性。
  • GS-CTV的D98和D95显著低于SC-CTV。
  • SC-CTV与GS-CTV的最大剂量(D2)无显著差异,且始终低于110%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To quantify the dosimetric impact of contouring variability of axillary lymph nodes (L2, L3, L4) in breast cancer (BC) locoregional radiotherapy (RT). MATERIALS AND METHODS: 18 RT centres were asked to plan a locoregional treatment on their own planning target volume (single centre, SC-PTV) which was created by applying their institutional margins to the clinical target volume of the axillary nodes of three BC patients (P1, P2, P3) previously delineated (SC-CTV). The gold standard CTVs (GS-CTVs) of P1, P2 and P3 were developed by BC experts' consensus and validated with STAPLE algorithm. For each participating centre, the GS-PTV of each patient was created by applying the same margins as those used for the SC-CTV to SC-PTV expansion and replaced the SC-PTV in the treatment plan. Datasets were imported into MIM v6.1.7 [MIM Software Inc.], where dose-volume histograms (DVHs) were extracted and differences were analysed. RESULTS: 17/18 centres used intensity-modulated RT (IMRT). The CTV to PTV margins ranged from 0 to 10 mm (median 5 mm). No correlation was observed between GS-CTV coverage by 95% isodose and GS-PTV margins width. Doses delivered to 98% (D98) and 95% (D95) of GS-CTVs were significantly lower than those delivered to the SC-CTVs. No significant difference between SC-CTV and GS-CTV was observed in maximum dose (D2), always under 110%. Mean dose ≥99% of the SC-CTVs and GS-CTVs was satisfied in 84% and 50%, respectively. In less than one half of plans, GS-CTV V95% was above 90%. Breaking down the GS-CTV into the three nodal levels (L2, L3 and L4), L4 had the lowest probability to be covered by the 95% isodose. CONCLUSIONS: Overall, GS-CTV resulted worse coverage, especially for L4. IMRT was largely used and CTV-to-PTV margins did not compensate for contouring issues. The results highlighted the need for delineation training and standardization.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Leonardi MC, Pepa M, Luraschi R, et al. The dosimetric impact of axillary nodes contouring variability in breast cancer radiotherapy: An AIRO multi-institutional study. Radiother Oncol. 2022. PMID: 35033602. doi:10.1016/j.radonc.2022.01.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。