文献速递胸部肿瘤放疗放疗物理与技术

肺癌放疗平均强度投影4D-CT上的心脏亚结构勾画:心脏瓣膜勾画图谱的提议

Contouring cardiac substructures on average intensity projection 4D-CT for lung cancer radiotherapy: A proposal of a heart valve contouring atlas.
PubMed 文献 · Radiother Oncol · 2022-01-03

研究开发了心脏瓣膜勾画图谱,并评估在平均强度投影四维非增强CT(AVE-4D-CT)上勾画心脏、其亚结构及冠状动脉的观察者间变异及其对放疗剂量的影响。结果显示该图谱使心脏瓣膜勾画具有可重复性,AVE-4D-CT上勾画心脏及其亚结构可行,观察者间变异与传统非增强CT相似。

要点

  • 心脏瓣膜勾画图谱使瓣膜勾画具有可重复性。
  • 肺动脉瓣、主动脉瓣、二尖瓣、三尖瓣的平均DSC分别为0.68、0.49、0.45、0.45。
  • 观察者间一致性在冠状动脉最低,剂量变异主要见于左心室间隔和前壁节段。

核心结论

  • 该图谱使心脏瓣膜勾画具有可重复性。
  • 在AVE-4D-CT上勾画心脏及其亚结构可行,观察者间变异与传统非增强CT扫描报道的相似。

研究设计与样本

  • 开发了心脏瓣膜勾画图谱。
  • 由5名放射肿瘤科医生和4名心脏科医生在10例接受放化疗的非小细胞肺癌(NSCLC)患者的AVE-4D-CT扫描上,按该图谱勾画瓣膜,按现有图谱勾画其余心脏亚结构。
  • 将观察者勾画与共同定义的「参考」勾画进行比较,并使用患者的治疗计划评估空间变异对放疗剂量的影响。

主要发现

  • 肺动脉瓣(PV)、主动脉瓣(AV)、二尖瓣(MV)和三尖瓣(TV)的观察者间勾画重叠(平均DSC)分别为0.68、0.49、0.45和0.45。
  • PV、AV、MV和TV的观察者间勾画分离(平均DAH)分别为2.1、3.4、2.6和2.9 mm。
  • TV和MV的平均HD(13.3和11.7 mm)高于AV和PV(7.8和7 mm)。
  • 平均MDA最高为AV的3.1 mm,最低为PV的1.9 mm。
  • 观察者间一致性在冠状动脉最低,但具有统计学意义的剂量变异主要见于左心室间隔和前壁节段。

关键数值与推荐

  • 肺动脉瓣、主动脉瓣、二尖瓣和三尖瓣的平均DSC分别为0.68、0.49、0.45和0.45。
  • 肺动脉瓣、主动脉瓣、二尖瓣和三尖瓣的平均DAH分别为2.1、3.4、2.6和2.9 mm。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: A detailed contouring atlas of the heart valves is lacking. Existing heart contouring atlases have not been evaluated on average intensity projection four-dimensional non-contrast computed tomography (AVE-4D-CT) scans, routinely used for organ-at-risk delineation in lung cancer radiotherapy. We aimed to develop the heart valve contouring atlas and to assess inter-observer variation in delineation of the heart, its substructures, and coronary arteries on AVE-4D-CT scans, along with its impact on radiotherapy doses. MATERIALS AND METHODS: A heart valve contouring atlas was developed. Five radiation oncologists and four cardiologists delineated the valves according to this atlas, and the remaining heart substructures according to the existing atlases, on AVE-4D-CT scans of ten patients who underwent radio(chemo)therapy for NSCLC. The observer contours were then compared to the collectively defined "reference" contours. Spatial variation was assessed using the Sørensen-Dice similarity coefficient (DSC), directed average Hausdorff distance (DAH), directed Hausdorff distance (HD), and the mean distance to agreement (MDA). The effect of spatial variation on radiotherapy doses was assessed using the patients' treatment plans. RESULTS: Inter-observer contour overlap (mean DSC) was 0.68, 0.49, 0.45 and 0.45, and inter-observer contour separation (mean DAH) was 2.1, 3.4, 2.6 and 2.9 mm for the pulmonic (PV), aortic (AV), mitral (MV) and tricuspid valve (TV), respectively. Mean HD was higher for TV and MV (13.3 and 11.7 mm) than for AV and PV (7.8 and 7 mm). The highest mean MDA of 3.1 mm was found for AV, and the lowest (1.9 mm) for PV. Inter-observer agreement was the lowest for the coronary arteries, but statistically significant dose variation was found mainly in the left ventricular septal and anterior segments. CONCLUSION: Our atlas enables reproducible delineation of the heart valves. Delineation of the heart and its substructures on AVE-4D-CT scans is feasible, with inter-observer variability similar to that reported on conventional non-contrast CT scans.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Socha J, Rygielska A, Uziębło-Życzkowska B, et al. Contouring cardiac substructures on average intensity projection 4D-CT for lung cancer radiotherapy: A proposal of a heart valve contouring atlas. Radiother Oncol. 2022. PMID: 34990727. doi:10.1016/j.radonc.2021.12.041

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。