文献速递胸部肿瘤放疗放疗物理与技术

基于MRI与CT的肺癌原发灶及淋巴结大体肿瘤体积勾画变异性

Variability of gross tumour volume delineation: MRI and CT based tumour and lymph node delineation for lung radiotherapy.
PubMed 文献 · Radiother Oncol · 2021-12-08

研究比较肺癌患者基于CT与PET、T2加权MRI与PET及T1加权MRI与PET的大体肿瘤体积(GTV)勾画。三位胸部放疗医生对26例患者勾画,观察者间变异以DSC评估,原发GTV平均DSC为0.9,淋巴结GTV的DSC大于0.7;T2和T1的GTVp与GTVn均小于CT,但体积差异无统计学意义;基于DSC指标,T2和T1的GTVp与GTVn相比CT的GTVp与GTVn差异有统计学意义(p<0.01)。

要点

  • 观察者间变异:原发GTV平均DSC为0.9,淋巴结GTV的DSC大于0.7。
  • T2和T1的GTVp与GTVn均小于CT,但体积差异无统计学意义。
  • 基于DSC指标,T2和T1的GTVp与GTVn相比CT差异有统计学意义(p<0.01)。

核心结论

  • MRI与PET联合勾画GTV的观察者间变异与CT与PET联合勾画相似。
  • MRI与CT勾画体积之间的显著差异需进一步探索。

研究设计与样本

  • 三位经验丰富的胸部放疗医生对26例肺癌患者进行GTV勾画。
  • 勾画基于配准至PET的CT、配准至PET的T2加权MRI及配准至PET的T1加权MRI。
  • 所有观察者接受了T1和T2图像审阅及窗宽窗位设置指导的培训。

主要发现

  • 观察者间变异:原发GTV(GTVp)所有观察者平均DSC为0.9,淋巴结GTV(GTVn)的DSC大于0.7。
  • T2和T1的GTVp与GTVn平均体积均小于CT的GTVp与GTVn,但不同模态间体积差异无统计学意义。
  • 基于DSC指标,T2和T1的GTVp与GTVn相比CT的GTVp与GTVn差异有统计学意义(p<0.01)。
  • 基于HD,观察者体积与STAPLE体积相比,体积相似性变异大,HD可达5.4 cm。

关键数值与推荐

  • 观察者间变异以DSC、HD和平均Hausdorff距离(AvgHD)指标评估。
  • 以每種图像模态的STAPLE体积作为参考体积计算观察者间变异(IOV)。
  • 模态间分析以每位观察者基于CT的原发和淋巴结GTV作为参考体积。

局限性

  • MRI与CT勾画体积之间的显著差异需进一步探索。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare gross tumour volume (GTV) delineation of lung cancer on magnetic resonance imaging (MRI) and positron emission tomography (PET) versus computed tomography (CT) and PET. METHODS: Three experienced thoracic radiation oncologists delineated GTVs on twenty-six patients with lung cancer, based on CT registered to PET, T2-weighted MRI registered to PET and T1-weighted MRI registered with PET. All observers underwent education on reviewing T1 and T2 images along with guidance on window and level setup. Interobserver and intermodality variation was performed based on dice similarity coefficient (DSC), Hausdorff distance (HD), and average Hausdorff distance (AvgHD) metrics. To compute interobserver variability (IOV) a simultaneous truth and performance level estimation (STAPLE) volume for each image modality was used as reference volume. For intermodality analysis, each observers CT based primary and nodal GTV was used as reference volume. RESULTS: A mean DSC of 0.9 across all observers for primary GTV (GTVp) and a DSC of >0.7 for nodal GTV (GTVn) was demonstrated for IOV. Mean T2 and T1 GTVp and GTVn were smaller than CT GTVp and GTVn but the difference in volume between modalities was not statistically significant. Significant difference (p < 0.01) for GTVp and GTVn was found between T2 and T1 GTVp and GTVn compared to CT GTVp and GTVn based on DSC metrics. Large variation in volume similarity was noted based on HD of up-to 5.4 cm for observer volumes compared to STAPLE volume. CONCLUSION: Interobserver variability in GTV delineation was similar for MRI and PET versus CT and PET. The significant difference between MRI compared to CT delineated volumes needs to be further explored.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Kumar S, Holloway L, Boxer M, et al. Variability of gross tumour volume delineation: MRI and CT based tumour and lymph node delineation for lung radiotherapy. Radiother Oncol. 2021. PMID: 34896156. doi:10.1016/j.radonc.2021.11.036

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。