文献速递免疫规划卫生政策与健康促进

口腔液体质量与采集方法校正可改善循环破伤风抗毒素预测

Adjustments for oral fluid quality and collection methods improve prediction of circulating tetanus antitoxin: Approaches for correcting antibody concentrations detected in a non-invasive specimen.
PubMed 文献 · Vaccine · 2020-11-27

该嵌套横断面分析纳入267名12至15月龄儿童,采用酶免疫测定法检测口腔液体和血清中的抗破伤风类毒素IgG。研究发现,在控制口腔液体总IgG和疫苗接种史后,口腔液体抗TT IgG是血清水平的良好替代指标,对口腔液体体积和总IgG浓度进行事后校正对血清学调查具有重要意义。

要点

  • 口腔液体抗TT IgG经总IgG和疫苗接种史校正后可替代血清抗体水平。
  • 标本带血、口腔溃疡和哭闹与口腔液体总IgG浓度正相关。
  • 口腔液体体积大和吸吮拭子与总IgG浓度负相关。

核心结论

  • 控制口腔液体总IgG和其他变量后,口腔液体抗TT IgG是血清水平的良好替代指标。
  • 采用口腔液体进行血清学调查时,应考虑对口腔液体体积和总IgG浓度进行事后校正。

研究设计与样本

  • 研究为嵌套于M-SIMU随机对照试验的横断面分析,纳入267名12至15月龄儿童。
  • 采集静脉血和口腔液体标本,记录采集困难(如哭闹、作呕)和口腔液体体积。
  • 采用酶免疫测定法检测口腔液体总IgG及口腔液体和血清中的抗TT IgG。

主要发现

  • 标本带血、口腔溃疡和哭闹与口腔液体总IgG浓度正相关。
  • 口腔液体体积大和吸吮拭子与口腔液体总IgG浓度负相关。
  • 校正总IgG(几何均值比1.99;95%CI:1.78-2.24)和疫苗接种史(几何均值比2.44;95%CI:1.98-3.01)后,上述因素均不是口腔液体抗TT IgG的显著预测因子。
  • 以口腔液体预测血清抗TT IgG时,口腔液体总IgG修饰了口腔液体抗TT IgG的效应。

临床怎么用

  • 在采用口腔液体进行破伤风血清学调查时,应检测并校正标本总IgG浓度和采集体积。
  • 口腔液体抗TT IgG经校正后可作为血清抗体水平的替代指标用于人群免疫评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To examine whether anti-tetanus toxoid (anti-TT) immunoglobulin G (IgG) levels measured in oral fluid and adjusted for collection difficulties and specimen quality are associated with total IgG and anti-TTIgG in oral fluid and assess if statistical adjustment for them improves prediction of anti-TT IgG in serum. METHODS: 267 children, ages 12 to 15 months, enrolled in the M-SIMU randomized controlled trial participated in this nested cross-sectional analysis. Venous blood and oral fluid (OF) specimens were collected, and OF collection difficulties such as crying or gagging were recorded. OF volume was documented and total IgG was measured in OF specimens and anti-TT IgG was measured in OF and serum by enzyme immunoassay (EIA). Collection difficulties, volume and sociodemographic characteristics were assessed in relation to total IgG and anti-TT IgG in OF via multivariate regression. These models were extended to evaluate the association between anti-TT IgG in OF and in serum. A prediction model was developed to adjust anti-TT IgG in OF estimates as proxy for serum. RESULTS: Blood in the specimen, sores in the mouth and crying were positively associated with total IgG concentration while high oral fluid volume and sucking on the swab were inversely associated. None were significant predictors of anti-TT IgG in OF after adjusting for total IgG (geometric mean [GM] ratio: 1.99; 95% confidence interval: 1.78-2.24) and vaccination history (GM ratio: 2.44; 95% CI: 1.98-3.01). When predicting anti-TT IgG levels in serum with OF, total IgG modified the effect of anti-TT IgG in OF. CONCLUSIONS: Anti-TT IgG in OF is a good proxy for levels in serum, after controlling for total IgG in the specimen and other variables. Post hoc adjustments for OF volume and total IgG concentration are an important consideration when conducting serosurveys with oral fluid.

来源:Vaccine,查看原文。版权归原作者所有。

引用

  1. Garrison-Desany H, Ochieng BO, Odiere MR, et al. Adjustments for oral fluid quality and collection methods improve prediction of circulating tetanus antitoxin: Approaches for correcting antibody concentrations detected in a non-invasive specimen. Vaccine. 2020. PMID: 33257104. doi:10.1016/j.vaccine.2020.11.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。