文献速递免疫规划卫生政策与健康促进

肺炎球菌参考血清007sp及第二套校准血清面板(Ewha QC血清面板B)对11种血清型的调理吞噬值赋值

Assignment of opsonic values to pneumococcal reference serum 007sp and a second pneumococcal OPA calibration serum panel (Ewha QC sera panel B) for 11 serotypes.
PubMed 文献 · Vaccine · 2020-11-06

该研究由五家实验室采用多重调理吞噬试验(OPA)检测11种肺炎球菌血清型,使用参考血清007sp标准化数据。标准化可显著降低部分血清型的实验室间变异,并为007sp的11种额外血清型及第二套校准血清面板(Ewha Panel B)建立共识值。

要点

  • 标准化OPA数据可降低部分血清型的实验室间变异,降幅因血清型而异。
  • 007sp对11种额外血清型的共识值及Ewha Panel B面板已建立。
  • 该共识值有助于下一代肺炎球菌结合疫苗(PCV)的研发。

核心结论

  • 使用参考血清007sp标准化OPA数据可显著降低部分血清型的实验室间变异,并为11种额外血清型建立共识值及第二套校准血清面板(Ewha Panel B)。

研究设计与样本

  • 五家实验室采用多重OPA检测血清型2、8、9N、10A、11A、12F、15B、17F、20B、22F和33F,每份样本测试5次,每次运行中007sp测试3次,结果用混合效应ANOVA模型分析。

主要发现

  • 标准化后,血清型2、8和11A的变异分别降低40%、45%和40%。
  • 血清型12F、17F和20B的变异降低较温和,分别为14%、19%和24%。
  • 标准化对剩余血清型影响很小,部分因接种后间隔较久采集的5份血清结果而削弱。

关键数值与推荐

  • 标准化后血清型2、8、11A的变异降低40%、45%、40%。
  • 标准化后血清型12F、17F、20B的变异降低14%、19%、24%。
  • 已报告007sp对13种血清型的共识值及Ewha Panel A,本研究新增11种血清型的共识值及Ewha Panel B。

临床怎么用

  • 在肺炎球菌疫苗免疫原性评估中,可使用007sp标准化OPA数据以减少实验室间变异。
  • 新一代PCV研发可参考007sp对11种额外血清型的共识值及Ewha Panel B校准血清面板。

局限性

  • 标准化对部分血清型效果有限,且接种后间隔较久采集的5份血清结果削弱了归一化的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Pneumococcal conjugate vaccines (PCVs) have been effective in reducing the disease burden caused by Streptococcus pneumoniae. The first licensed PCV (PCV7) was composed of capsular polysaccharides from seven serotypes. This was followed by PCV10, then PCV13, and currently there are a number of higher valency vaccines in development. As part of licensure, new vaccine iterations require assessment of immunogenicity. Since some antibodies can be non-functional, measuring functional antibodies is desirable. To meet this need, opsonophagocytic assays (OPAs) have been developed. Previous studies have shown there can be significant variations in OPA results from different laboratories. We have previously shown that standardizing OPA data using reference serum 007sp can decrease this variation. To extend this approach to additional serotypes, a panel of sera was tested by five laboratories using a multiplexed OPA for serotypes 2, 8, 9N, 10A, 11A, 12F, 15B, 17F, 20B, 22F, and 33F. Each sample was tested in five runs with 007sp tested three times in each run. Results were analyzed using a mixed effects ANOVA model. Standardization of the results significantly decreased the inter-laboratory variation for some serotypes. For serotypes 2, 8, and 11A, the variability was reduced by 40%, 45%, and 40%, respectively. For serotypes 12F, 17F, and 20B, the reductions were more modest (14%, 19%, and 24%, respectively). Standardization had little effect for the remaining serotypes. In many cases, the impact of normalization was blunted by the results from five sera that were collected after an extended post-vaccination interval. We have previously reported consensus values for 007sp for 13 serotypes, as well as the creation of a calibration serum panel ("Ewha Panel A"). Here, we report consensus values for 11 additional serotypes for 007sp and the creation of a second serum panel ("Ewha Panel B"). These consensus values will facilitate the development of next-generation PCVs.

来源:Vaccine,查看原文。版权归原作者所有。

引用

  1. Burton RL, Kim HW, Lee S, et al. Assignment of opsonic values to pneumococcal reference serum 007sp and a second pneumococcal OPA calibration serum panel (Ewha QC sera panel B) for 11 serotypes. Vaccine. 2020. PMID: 33162203. doi:10.1016/j.vaccine.2020.10.085

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。