文献速递免疫规划传染病防控与疫情报告

无针喷射注射器在灭活脊髓灰质炎疫苗入户接种活动中应用的可行性

Feasibility of jet injector use during inactivated poliovirus vaccine house-to-house vaccination campaigns.
PubMed 文献 · Vaccine · 2018-07-03

在766户家庭中,为6-59月龄儿童使用Pharmajet®无针肌内喷射注射器接种灭活脊髓灰质炎疫苗,共完成993次注射;接种员在16%(n=158)的注射中遇到装置准备困难,32名受访接种员中91%认为主要优点是无锐器处置,90%认为主要缺点是家长不接受(与疫苗而非装置有关),81%表示喷射注射器并不比针筒和针头更易使用。

要点

  • 无针喷射注射器用于入户接种活动是可行的。
  • 接种员认为装置不易使用,81%表示并不比针筒和针头更易使用。
  • 家长拒绝主要与频繁的脊灰疫苗接种活动有关,而非装置本身。

核心结论

  • 无针喷射注射器用于入户接种活动是可行的。
  • 接种员接受度低,81%表示喷射注射器并不比针筒和针头更易使用。
  • 家长因频繁脊灰疫苗接种活动而拒绝是最大挑战,装置的新颖性也给团队带来挑战,需在活动前开展有针对性的社会动员。

研究设计与样本

  • 在766户家庭中,为6-59月龄儿童使用Pharmajet®无针肌内喷射注射器接种灭活脊髓灰质炎疫苗,并收集装置可行性与 caregiver 及接种员接受度数据。

主要发现

  • 共完成993次注射。
  • 接种员在16%(n=158)的注射中遇到装置准备困难,与装载注射器及缺乏平坦表面用于装置设置有关。
  • 32名接种员受访,91%认为主要优点是无锐器处置,90%认为主要缺点是家长不接受,且与疫苗而非装置有关。
  • 81%的接种员表示喷射注射器并不比针筒和针头更易使用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To attain high coverage during polio vaccination campaigns, an outreach house-to-house strategy is used to administer oral poliovirus vaccine. Administering an injectable vaccine house-to-house requires a skilled work force and increases risks of needle stick injuries. Needle-free injection devices provide a safer alternative to needles and syringes for administering injectable vaccines. We evaluated the feasibility and acceptability of a needle-free injection device to administer injectable poliovirus vaccine during a house-to-house vaccination outreach activity. METHODS: Vaccination teams administered injectable poliovirus vaccine using the Pharmajet® needle-free intramuscular jet injector to children ages 6-59 months in 766 homes. Data on the feasibility of using the jet injector in an outreach campaign setting and the acceptability of the jet injector by caregivers and vaccinators were collected. RESULTS: A total of 993 injections were administered. Vaccinators faced challenges during device preparation in 16% (n = 158) of injections; challenges were related to problems loading the injector and not having a flat surface to use for setup of the injector. Among 32 vaccinators interviewed after the vaccination campaign, the main reported advantage of the device was absence of sharps disposal (91%) while the main reported disadvantage was unacceptability by parents (90%) which was related to the vaccine, not the device. CONCLUSIONS: The needle-free jet injector was feasible for use in house-to-house campaigns. Acceptability by vaccinators was low as 81% stated that the jet injector was not easier to use than needle and syringe. Parental refusal related to frequent polio vaccination campaigns was the biggest challenge. In addition, novelty of the device posed a challenge to teams as they needed to reassure parents about safety of the device. To take full advantage of the ability to take injectable vaccines door-to-door during vaccination campaigns using a needle-free jet injector device, tailored social mobilization efforts are needed ahead of campaigns.

来源:Vaccine,查看原文。版权归原作者所有。

引用

  1. Farag NH, Mansour Z, Torossian L, et al. Feasibility of jet injector use during inactivated poliovirus vaccine house-to-house vaccination campaigns. Vaccine. 2018. PMID: 29980387. doi:10.1016/j.vaccine.2018.06.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。