半导体二极管激光装置辅助皮内疫苗接种
本文报告一种手持近红外激光装置,采用1061、1258或1301纳米半导体二极管,成本低于4000美元,可在流感疫苗接种小鼠模型中复现二极管泵浦固态激光系统的佐剂效应,并提示更宽范围近红外波长具有增强疫苗免疫应答的能力。
要点
- 手持近红外半导体二极管激光装置成本低于4000美元,可复现二极管泵浦固态激光系统的佐剂效应。
- 该装置采用1061、1258或1301纳米波长,在流感疫苗接种小鼠模型中验证。
- 更宽范围近红外激光波长具有增强疫苗免疫应答的能力。
核心结论
- 小型低成本装置确立了激光佐剂方法用于临床环境大规模疫苗接种规划的可行性,为多种疫苗更广泛测试该技术打开大门,并为开发临床可用装置奠定基础。
研究设计与样本
- 临床前研究:在流感疫苗接种小鼠模型中,比较手持近红外激光装置与二极管泵浦固态激光系统的佐剂效应。
主要发现
- 手持近红外激光装置使用发射1061、1258或1301纳米光的半导体二极管,成本低于4000美元。
- 该装置在小鼠流感疫苗接种模型中复现了二极管泵浦固态激光系统的佐剂效应。
- 结果表明更宽范围近红外激光波长具有增强疫苗免疫应答的能力。
临床怎么用
- 作者认为该小型低成本装置确立了激光佐剂方法用于临床环境大规模疫苗接种规划的可行性。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
A brief exposure of skin to a low-power, non-tissue damaging laser light has been demonstrated to augment immune responses to intradermal vaccination. Both preclinical and clinical studies show that this approach is simple, effective, safe and well tolerated compared to standard chemical or biological adjuvants. Until now, these laser exposures have been performed using a diode-pumped solid-state laser (DPSSL) devices, which are expensive and require labor-intensive maintenance and special training. Development of an inexpensive, easy-to-use and small device would form an important step in translating this technology toward clinical application. Here we report that we have established a handheld, near-infrared (NIR) laser device using semiconductor diodes emitting either 1061, 1258, or 1301nm light that costs less than $4000, and that this device replicates the adjuvant effect of a DPSSL system in a mouse model of influenza vaccination. Our results also indicate that a broader range of NIR laser wavelengths possess the ability to enhance vaccine immune responses, allowing engineering options for the device design. This small, low-cost device establishes the feasibility of using a laser adjuvant approach for mass-vaccination programs in a clinical setting, opens the door for broader testing of this technology with a variety of vaccines and forms the foundation for development of devices ready for use in the clinic.
引用
- Kimizuka Y, Callahan JJ, Huang Z, et al. Semiconductor diode laser device adjuvanting intradermal vaccine. Vaccine. 2017. PMID: 28365253. doi:10.1016/j.vaccine.2017.03.036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。