使用单个或多个对照时间序列分析计数结局的间断时间序列
针对计数结局的间断时间序列分析,提出基于条件泊松似然的框架,可纳入单个或多个对照序列。方法通过数据驱动方式检验干预与对照序列是否共享共同时变成分,并在错误设定下用稳健方差估计保证推断有效。两个实例分别评估佛罗里达州「坚守阵地法」对枪杀的影响和加纳轮状病毒疫苗引入效果。
要点
- 条件泊松框架适用于计数结局的对照间断时间序列分析。
- 多对照序列在共享时变成分假设下可提高估计精度。
- 数据驱动方法可检验干预与对照序列是否共享时变成分。
核心结论
- 条件泊松方法为计数结局的间断时间序列分析提供了实用的似然框架。
- 当共同时变成分假设成立时,纳入多个对照序列可更精确地估计目标参数。
研究设计与样本
- 方法学开发研究,提出基于条件泊松似然的框架,并用两个真实数据集演示应用。
主要发现
- 佛罗里达州「坚守阵地法」对枪杀影响的实例中,使用其他州凶杀率作为多对照序列可得到更准确的推断。
- 加纳轮状病毒疫苗引入的实例展示了共同时变成分假设不成立时的分析流程。
- 稳健方差估计可在假定分布错误设定时提供有效的统计推断。
临床怎么用
- 分析计数结局的间断时间序列时,可考虑采用条件泊松框架并纳入对照序列。
- 纳入多对照序列前应评估共同时变成分假设是否成立。
- 假设不成立时需采用更灵活的建模方式,并可用稳健方差估计保障推断。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Interrupted time series (ITS) analysis is a widely used quasi-experimental design for evaluating the impact of population-level interventions. To control for confounding from concurrent events, researchers often incorporate control time series. However, for count outcomes, especially with control series, methodological development remains limited. DEVELOPMENT: We introduce a likelihood-based framework for controlled ITS analysis with count data. The proposed framework is based on a conditional Poisson likelihood and naturally extends to settings with multiple control series. This analysis is straightforward when the intervention and control series share a common time-varying component, whereas more flexible modeling is required when such shared structure is not supported. We describe a data-driven method for assessing whether the intervention and control series share a common time-varying component. We also show that, with robust variance estimation, the proposed approach can provide valid statistical inference even if the assumed distribution is misspecified. APPLICATION: We demonstrate the method using two real datasets. The first example assesses the effect of Florida's Stand Your Ground (SYG) law on firearm-related homicides and illustrates how the use of multiple control series (homicide rates in other states) leads to more accurate inference. The second example evaluates rotavirus vaccine introduction in Ghana and demonstrates how the analysis proceeds when the common time-varying component assumption is not supported. CONCLUSIONS: The proposed conditional Poisson approach provides a practical likelihood-based framework for analyzing ITS with count outcomes using single or multiple control time series. When the common time-varying component assumption holds, incorporating multiple control series can lead to more precise estimation of the parameter of interest.
引用
- Zheng X, Bottomley C, Lee W, et al. Analyzing interrupted time series with count outcomes using single or multiple control time series. Int J Epidemiol. 2026. PMID: 42706679. doi:10.1093/ije/dyag199
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。