文献速递环境卫生卫生政策与健康促进慢病防控与筛查

伦敦超低排放区对儿童肺功能增长的影响:前瞻性平行队列研究

Impact of the Ultra Low Emission Zone on lung function growth in children in London, UK: a prospective parallel cohort study.
PubMed 文献 · Lancet Public Health · 2026-08-18

该研究评估伦敦超低排放区(ULEZ)对儿童肺功能增长轨迹的影响,比较伦敦与卢顿6-9岁儿童5年随访的FEV1。结果显示伦敦儿童FEV1年增长率比卢顿高10 mL/年(95%CI 5-15),NO2暴露下降更快,4年后FEV1均值达到相同水平。

要点

  • 伦敦儿童FEV1年增长比卢顿多10 mL/年(95%CI 5-15),4年后均值持平。
  • 伦敦NO2年下降3·77 μg/m3,卢顿下降1·77 μg/m3,差异显著。
  • 伦敦临床肺功能受损比例从14%降至9%,卢顿从9%降至7%。

核心结论

  • 伦敦实施ULEZ与儿童肺功能增长轨迹改善相关,提示先前肺发育缺陷得到恢复。
  • 证据支持更广泛地实施清洁空气区作为公共卫生干预措施。

研究设计与样本

  • 前瞻性、双臂、平行队列研究(CHILL研究),招募伦敦和卢顿6-9岁儿童。
  • 2018年6月5日至2019年4月4日招募3414名儿童,3209名(94·0%)纳入FEV1分析。
  • 每年学校访问测量肺功能,使用经验证的扩散模型估算家庭地址NO2、PM10、PM2·5年暴露。
  • 使用混合效应线性回归比较两地肺功能增长及空气污染暴露与肺增长的关联。

主要发现

  • 基线调整后FEV1伦敦比卢顿低38 mL(95%CI -58至-18;p=0·0002)。
  • 基线NO2年暴露伦敦比卢顿高18·95 μg/m3(95%CI 18·51至19·38;p<0·0001)。
  • 随访期间伦敦FEV1增长233 mL/年,卢顿223 mL/年,伦敦多增10 mL/年(95%CI 5至15;p=0·0002)。
  • NO2暴露伦敦年降3·77 μg/m3,卢顿年降1·77 μg/m3(p<0·0001)。
  • 4年后FEV1均值伦敦2283 mL(95%CI 2207至2354),卢顿2282 mL(95%CI 2185至2376)。

临床怎么用

  • 清洁空气区政策可改善儿童肺功能发育,支持在交通污染城市推广。
  • 监测儿童肺功能及NO2等暴露可为评估政策健康效益提供依据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Traffic-related air pollution is a risk factor for lung disease and early mortality. Clean air zones are public health policy interventions used to reduce traffic-related air pollution in urban areas, but evidence of their health benefits is limited. We describe a natural experiment study evaluating the impact of the Ultra Low Emission Zone (ULEZ) in London, UK. The primary aim was to assess the impact of the ULEZ on children's lung function growth trajectories, by comparing forced expiratory volume in 1 s (FEV1) measurements over 5 years between children in London and Luton, UK. METHODS: The Children's Health in London and Luton (CHILL) study is a prospective, two-arm, parallel cohort study. We recruited children aged 6-9 years from primary schools in central London (the original area of the ULEZ implementation) and Luton (a comparator site with no clean air zone). Children were excluded if they had symptoms of lung disease (excluding asthma) or learning or physical disabilities preventing them from giving informed assent. Lung function was measured by spirometry at annual school visits at baseline (before ULEZ implementation) and over the following 4 years. Annual residential exposures to nitrogen dioxide (NO2) and particulate matter with aerodynamic diameters of less than 10 μm (PM10) and less than 2·5 μm (PM2·5) were estimated at each child's home address at 20 m2 resolution using a validated dispersion modelling system. The primary outcome was the annual rate of lung function growth, measured as post-bronchodilator FEV1 over the 5-year study period. We assessed growth trajectories against individualised residential exposure to NO2, PM10, and PM2·5. We used mixed-effects linear regression to compare lung function growth between London and Luton and to examine associations between air pollution exposures and lung growth. FINDINGS: Of 122 schools approached, 84 (69%) agreed to participate (44 schools in London; 40 schools in Luton). Of 9419 children invited, we recruited 3414 children (1664 in London and 1750 in Luton) between June 5, 2018, and April 4, 2019, before ULEZ implementation. 3209 (94·0%) of 3414 children were included in the FEV1 analysis (1557 children in London, 1652 children in Luton). Children were similar across the two sites in terms of age, height, and weight, with a higher proportion of girls in London (867 [56%] of 1557) than in Luton (809 [49%] of 1652). Baseline adjusted FEV1 was lower in London than Luton (difference -38 mL, 95% CI -58 to -18; p=0·0002). At baseline, children's modelled annual exposures to NO2, the pollutant most reflective of exhaust emissions, were 18·95 μg/m3 (95% CI 18·51 to 19·38; p<0·0001) higher in London than in Luton. Over the follow-up period, children's FEV1 growth increased by 10 mL/year (95% CI 5 to 15; p=0·0002) more in London than in Luton (233 mL/year vs 223 mL/year), with modelled residential exposures to NO2 decreasing faster in London than in Luton (decreases of -3·77 μg/m3 per year in London vs -1·77 μg/m3 per year in Luton; p<0·0001). After 4 years, mean FEV1 reached parity across sites: 2283 mL (2207 to 2354) in London; 2282 mL (2185 to 2376) in Luton. The proportion of children with clinically impaired lung function fell from 184 (14%) of 1280 children to 51 (9%) of 585 children in London, and from 126 (9%) of 1339 children to 41 (7%) of 606 children in Luton. INTERPRETATION: Introduction of the London ULEZ was associated with improved lung function growth trajectories in children in London compared with children in Luton, suggesting that previous deficits in lung development were restored. This evidence supports wider implementation of clean air zones as a public health intervention. FUNDING: National Institute for Health and Care Research and Natural Environment Research Council UK Research and Innovation.

来源:Lancet Public Health,查看原文。版权归原作者所有。

引用

  1. Wood HE, Hajmohammadi H, Dove RE, et al. Impact of the Ultra Low Emission Zone on lung function growth in children in London, UK: a prospective parallel cohort study. Lancet Public Health. 2026. PMID: 42612665. doi:10.1016/S2468-2667(26)00163-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。