文献速递传染病防控与疫情报告环境卫生

法国2019年一起与集体生物质冷凝锅炉相关的社区军团病疫情

A community Legionnaires' disease outbreak linked to a collective biomass condensing boiler, France, 2019.
PubMed 文献 · Euro Surveill · 2025-01-01

2019年11月1日至12月12日,法国斯特拉斯堡大都会区发生军团病疫情,共诊断28例(男14例、女14例),中位年龄70岁(范围42-88岁),2例死亡。通过流行病学、环境和基因组学调查(包括嵌套序列分型与全基因组测序),将疫情源头定位至一处供热厂的生物质冷凝锅炉,该处发现高浓度Lp 1污染(10^5-10^6 CFU/L),环境与临床分离株序列聚类差异为0至2个单核苷酸多态性。

要点

  • 28例军团病病例中9例为Lp 1 ST62型感染,2例死亡。
  • 病例 incubation 期活动地图指向斯特拉斯堡市西南部为疫情中心。
  • 供热厂生物质冷凝锅炉内发现高浓度Lp 1污染(10^5-10^6 CFU/L),8株环境分离株为ST62。

核心结论

  • 此次疫情与供热厂生物质冷凝锅炉中Lp 1增殖及锅炉烟气播散有关,提示节能供热工艺可能存在军团病风险。

研究设计与样本

  • 对2019年11月1日至12月12日斯特拉斯堡大都会区军团病疫情开展流行病学、环境和基因组学调查(嵌套序列分型与全基因组测序)。
  • 共诊断28例病例(男14例、女14例),中位年龄70岁(范围42-88岁),其中2例死亡。

主要发现

  • 9例病例经分型确认为Lp 1 ST62型感染。
  • 病例 incubation 期活动地图指向斯特拉斯堡市西南部为疫情中心。
  • 供热厂生物质冷凝锅炉内发现高浓度Lp 1污染(10^5-10^6 CFU/L)。
  • 厂内8株环境Lp 1分离株为ST62型。
  • 环境与临床ST62分离株全基因组测序序列聚类差异为0至2个单核苷酸多态性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Between 1 November and 12 December 2019, a Legionnaires' disease (LD) outbreak occurred in the Strasbourg metropolitan area, France. Epidemiological, environmental and genomic investigations (nested sequence-based typing and whole genome sequencing (WGS)) were undertaken to locate the outbreak source, characterise the causal Legionella strain, and understand its spread. Through a positive urinary antigen test, 28 cases (14 male; 14 female) with 70 years median age (range: 42-88 years) were diagnosed. Two died. For nine cases, typing revealed L. pneumophila serogroup 1 (Lp 1) sequence type (ST) 62 infection. Mapping where cases were during their incubation period pointed to a place south-west of Strasbourg city as the outbreak epicentre. There, in the biomass condensing boiler of a heating plant, high Lp 1 contamination levels (105-106 CFU/L) were discovered. Eight environmental Lp 1 isolates from inside the plant were ST62. Analysing WGS data from these isolates and the nine Lp 1 ST62 clinical isolates, found their sequences clustering with zero to two single nt polymorphisms. Sub-optimal maintenance and warm weather before the boiler started operating may have allowed Lp 1 proliferation within, with boiler fumes subsequently disseminating Lp 1, thereby exposing people. This outbreak highlights potential LD risks arising from innovative energy-saving heat production processes designed to reduce greenhouse gas emissions.

来源:Euro Surveill,查看原文。版权归原作者所有。

引用

  1. Raguet S, Ginevra C, Descours G, et al. A community Legionnaires' disease outbreak linked to a collective biomass condensing boiler, France, 2019. Euro Surveill. 2025. PMID: 41104494. doi:10.2807/1560-7917.ES.2025.30.41.2400804

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。