肺炎球菌13价结合疫苗对肺癌患者的FTIR监测:酰胺振动变化与生化检测相关
研究纳入103例III和IV期肺癌患者(52±9岁),在接种13价肺炎球菌结合疫苗前及接种后7天和30天采集血清,用生化检测和傅里叶变换红外光谱分析。结果显示接种后IgG和IgG2浓度较接种前升高,FTIR光谱中酰胺振动吸光度也升高,且接种后7天与30天之间酰胺吸光度无差异。主成分分析可区分三组样本,仅在接种后30天组观察到生化IgG与FTIR结果的相关性。
要点
- 肺癌患者接种13价肺炎球菌结合疫苗后IgG和IgG2浓度较接种前升高。
- FTIR光谱显示接种后酰胺振动吸光度升高,与生化免疫球蛋白结果一致。
- 接种后7天与30天之间酰胺吸光度无差异,主成分分析可区分三组样本。
核心结论
- 肺癌患者接种13价肺炎球菌结合疫苗后,血清IgG和IgG2浓度较接种前升高,FTIR光谱中酰胺振动吸光度也升高,仅在接种后30天组观察到生化IgG与FTIR结果的相关性。
研究设计与样本
- 研究纳入肺癌患者103例,年龄52±9岁,III和IV期占79%,在接种13价肺炎球菌结合疫苗前及接种后7天和30天采集血清,进行生化检测和傅里叶变换红外光谱分析。
主要发现
- 接种后患者IgG和IgG2浓度较接种前升高。
- FTIR光谱显示接种后酰胺振动吸光度较接种前升高。
- 接种后7天与30天之间酰胺吸光度无差异。
- FTIR光谱显示接种后组酰胺I与酰胺III比值及酰胺II与酰胺III比值发生变化。
- 酰胺I区(1600 cm-1-1700 cm-1)去卷积显示接种后血清α-螺旋与β-折叠比值较接种前降低约0.05。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Lung cancer is one of the most lethal cancers. Unfortunately, respiratory tract infections are very common in lung cancer patients, delaying appropriate anticancer therapy. To increase therapy efficiency, in this study we examined the effect of 13-Valent Pneumococcal Conjugate Vaccine on the immune response in lung cancer patients, which indirectly affects the success of anticancer therapy. The study was done using biochemical tests and Fourier Transform InfraRed (FTIR) spectroscopy. For this purpose, serum from lung cancer patients aged 52 ± 9 years (III and IV clinical stage; 79 %; n = 103) before and seven as well as 30 days after vaccination was collected. Obtained results showed increasing concentrations of immunoglobulin IgG and IgG2 groups in patients after vaccination in comparison with group before vaccination. This result was confirmed by FTIR spectroscopy, where higher absorbances of amides vibrations were observed after vaccination. Interestingly, lack of differences in the amides absorbances between patients 7 and 30 days after vaccination were noticed. FTIR spectra also showed changes in the ratio between amide I and amide III as well as between amide II and amide III in the groups of patients after vaccination. From deconvolution of made I range (1600 cm-1-1700 cm-1) decrease of the ratio between α-helix and β-sheet around 0.05 was noticed in serum collected from patients after vaccination in comparison with patients before vaccination. Using Principal Component Analysis (PCA) analysis of FTIR data it was observed that serum collected from all three analyzed groups of samples was possible to differentiate. The highest accuracy in differentiation group of samples before and 7 days after vaccination was visible in amide I, while before and 30 days after vaccination using amide II. Correlation between immunoglobulin IgG and IgG2 concentrations obtained by biochemical assays and FTIR were noticed only in the group of serum collected 30 days after vaccination, which suggested that FTIR spectroscopy reflects biochemical data.
引用
- Smok-Kalwat J, Góźdź S, Macek P, et al. FTIR monitoring of the 13-valent pneumococcal conjugate vaccine for lung cancer patients: Changes in amides vibrations correlated with biochemical assays. Vaccine. 2024. PMID: 39427598. doi:10.1016/j.vaccine.2024.126459
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。