疫苗接种态度检查(VAX)量表阿拉伯语译本的验证
研究将12条目四子量表的疫苗接种态度检查(VAX)量表从丹麦语翻译为阿拉伯语,于2023年3月通过在线调查系统及作者网络发放给沙特阿拉伯公民,分析164名完整作答者数据。验证性因子分析确认四因子结构拟合良好,Cronbach α为0.874至0.930,未接种者各子量表均分高于完全接种者及完全接种加加强针者(p < 0.05)。
要点
- 验证性因子分析确认阿拉伯语VAX四因子结构拟合良好,标准化回归权重0.69至0.96。
- 内部一致性信度Cronbach α为0.874至0.930,四因子间相关系数0.47至0.79。
- 未接种COVID-19疫苗者各子量表均分高于完全接种者及完全接种加加强针者(p < 0.05)。
核心结论
- 阿拉伯语译本VAX具有定义明确的因子结构、良好的内部一致性信度和已知组效度。
- 该工具可用于阿拉伯语国家或人群的疫苗犹豫测量,并支持跨国家与跨文化的疫苗犹豫比较。
研究设计与样本
- 将VAX从丹麦语翻译为阿拉伯语,遵循患者报告结局测量翻译与文化适应良好实践原则。
- 2023年3月通过在线调查系统及作者网络向沙特阿拉伯公民发放翻译版VAX。
- 分析164名完整作答问卷的参与者数据;平均年龄40岁,77%为女性,90%完全接种COVID-19疫苗,其中三分之一接种了加强针。
- 采用Cronbach α评估内部一致性信度,验证性因子分析(CFA)检验因子结构,基于COVID-19疫苗接种状态评估已知组效度。
主要发现
- 验证性因子分析确认四因子结构拟合良好,所有条目在其因子上载荷良好,标准化回归权重值为0.69至0.96。
- 四因子间相关系数为0.47至0.79。
- Cronbach α为0.874至0.930。
- 未接种者所有子量表均分高于完全接种者及完全接种加加强针者(p < 0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIM: The availability of concise and valid instruments for measuring vaccination attitudes across different countries or populations is limited. The 12-item four-subscale Vaccination Attitudes Examination (VAX) scale designed to assess vaccination hesitancy has been validated in more than 15 languages. This study aimed to validate the Arabic translation of VAX. METHODS: VAX was translated from Danish to Arabic following the Principles of Good Practice for the Translation and Cultural Adaptation Process for Patient-Reported Outcome Measures. The translated VAX was distributed to the citizens of Saudi Arabia in March 2023 through an online survey system and the authors' networks. Internal consistency reliability was assessed with Cronbach's α. Factorial structure was examined using confirmatory factor analysis (CFA). Known-group validity was assessed based on COVID-19 vaccination status. RESULTS: Responses from 164 participants who fully answered the questionnaire were analyzed. The mean age was 40 years, 77 % were females, and 90 % were fully vaccinated against COVID-19, with one-third receiving booster doses. CFA confirmed a well-fit four-factor structure. All items loaded well with their factors: standardized regression weight values ranged from 0.69 to 0.96. Correlations between the four factors ranged from 0.47 to 0.79. Cronbach α ranged from 0.874 to 0.930. As expected, the mean scores of all subscales were higher in those unvaccinated compared to those who were fully vaccinated as well as those fully vaccinated with a booster dose (p < 0.05). CONCLUSION: The Arabic translation of the VAX exhibited a well-defined factorial structure with good internal consistency reliability and known-group validity. It is a valuable tool for measuring vaccination hesitancy in Arabic-speaking countries or populations, enabling the comparison of vaccine hesitancy across different countries and cultures.
引用
- Alansari KDH, Buhl C, Thabit AK, et al. Validation of the Arabic translation of the vaccination attitudes examination (VAX) scale. Vaccine. 2024. PMID: 39368127. doi:10.1016/j.vaccine.2024.126411
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。