法国某医院血液科重症监护病房产碳青霉烯酶法氏柠檬酸杆菌暴发与一间病房持续性废水储库相关,2019至2022年
2019至2022年,法国某血液科重症监护病房发生产OXA-48法氏柠檬酸杆菌持续暴发,共检出8例病例(7例定植,1例感染并死亡),所有病例均住同一病房。环境采样从该病房浴室淋浴、洗手池排水管和废水排水管检出同源菌株,分子分型显示环境与病例分离株不可区分。尽管采取集束控制措施,细菌仍在系统中持续存在并传播给新患者,废水排放管设计缺陷促成持续与增殖,最终关闭病房并重建浴室。
要点
- 8例病例均住同一病房,7例定植、1例感染并死亡。
- 环境与病例分离株分子分型不可区分,来源为浴室废水系统。
- 集束措施未能清除细菌,废水排放管设计缺陷促成持续存在。
核心结论
- 产OXA-48法氏柠檬酸杆菌在血液科重症监护病房持续暴发,与同一病房浴室废水储库相关,集束措施未能阻断传播,最终关闭病房并重建浴室。
研究设计与样本
- 2019至2022年于法国某医院血液科重症监护病房开展的暴发调查,共检出8例病例,并进行环境采样与分子分型。
主要发现
- 2019年4月从2例患者直肠拭子检出产OXA-48法氏柠檬酸杆菌,两例住同一病房但相隔4个月。
- 筛查两例之间住该病房的5例患者,发现第3例病例。
- 此后3年又检出5例,最后1例在2022年9月,共8例:7例定植,1例感染并死亡。
- 从该病房浴室淋浴、洗手池排水管和废水排水管检出产OXA-48法氏柠檬酸杆菌。
- 分子分型确认环境与病例的所有法氏柠檬酸杆菌分离株不可区分。
临床怎么用
- 尽管采取集束控制措施,细菌仍在系统中持续存在并传播给新患者。
- 废水排放管 placement 的设计缺陷促成细菌持续与增殖。
- 最后一例后关闭病房并重建浴室。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
In 2019-2022, a prolonged outbreak of oxacillinase (OXA)-48-producing Citrobacter farmeri due to a persistent environmental contamination, occurred in our haematology intensive care unit. In April 2019, we isolated OXA-48-producing C. farmeri from rectal samples of two patients in weekly screenings. The cases had stayed in the same hospital room but 4 months apart. We screened five patients who had stayed in this room between the two cases and identified a third case. Over the following 3 years, five other cases were detected, the last case in September 2022. In total, eight cases were detected: seven colonised with the bacterium and one infected with a lethal outcome. All cases stayed in the same hospital room. We detected OXA-48-producing C. farmeri from a shower, washbasin drains and wastewater drainage of the bathroom of the hospital room. Molecular typing confirmed that all C. farmeri isolates from the environment and the cases were indistinguishable. Despite bundle measures to control the outbreak, the bacterium persisted in the system, which resulted in transmission to new patients. A design defect in the placement of wastewater drains contributed to the persistence and proliferation of the bacterium. The room was closed after the last case and the bathroom rebuilt.
引用
- Regad M, Lizon J, Alauzet C, et al. Outbreak of carbapenemase-producing Citrobacter farmeri in an intensive care haematology department linked to a persistent wastewater reservoir in one hospital room, France, 2019 to 2022. Euro Surveill. 2024. PMID: 38577805. doi:10.2807/1560-7917.ES.2024.29.14.2300386
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。