重性抑郁障碍脑结构不对称性未见改变:ENIGMA联盟分析
该研究基于ENIGMA联盟31个数据集共2256例重性抑郁障碍患者与3504名对照的T1加权MRI数据,分析34个大脑皮层区域厚度与表面积及8个皮层下结构体积的偏侧化差异。结果显示最大效应量为0.085(颞上皮质厚度不对称),多重检验校正后不显著,且不对称指标与用药、急性/缓解状态、首发/复发及起病年龄均无显著关联。结论提示脑宏观结构不对称性改变在多数重性抑郁障碍病因学中可能意义甚微。
要点
- 重性抑郁障碍与健康对照的脑皮层厚度、表面积及皮层下体积不对称性均无显著差异。
- 最大效应量为0.085(颞上皮质厚度不对称),校正后不显著。
- 不对称指标与用药、急性/缓解状态、首发/复发及起病年龄无显著关联。
核心结论
- 脑宏观解剖不对称性改变在多数重性抑郁障碍病例的病因学中可能意义甚微。
研究设计与样本
- 采用ENIGMA联盟31个数据集,分析2256例重性抑郁障碍患者与3504名对照的34个皮层区域厚度和表面积偏侧化。
- 采用32个数据集,分析2540例重性抑郁障碍患者与4230名对照的8个皮层下结构体积不对称性。
- T1加权MRI数据以统一协议经FreeSurfer和Desikan-Killiany图谱处理。
- 大样本提供80%效能检测Cohen's d=0.1量级的效应。
主要发现
- 重性抑郁障碍诊断对颞上皮质厚度不对称的最大效应量为Cohen's d=0.085,多重检验校正后不显著。
- 不对称指标与用药、急性相比缓解状态、首发相比复发状态及起病年龄均无显著关联。
临床怎么用
- 临床不宜将脑宏观结构不对称性作为重性抑郁障碍的诊断或病因学评估指标。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Asymmetry is a subtle but pervasive aspect of the human brain, and it may be altered in several psychiatric conditions. MRI studies have shown subtle differences of brain anatomy between people with major depressive disorder and healthy control subjects, but few studies have specifically examined brain anatomical asymmetry in relation to this disorder, and results from those studies have remained inconclusive. At the functional level, some electroencephalography studies have indicated left fronto-cortical hypoactivity and right parietal hypoactivity in depressive disorders, so aspects of lateralized anatomy may also be affected. The authors used pooled individual-level data from data sets collected around the world to investigate differences in laterality in measures of cortical thickness, cortical surface area, and subcortical volume between individuals with major depression and healthy control subjects. METHODS: The authors investigated differences in the laterality of thickness and surface area measures of 34 cerebral cortical regions in 2,256 individuals with major depression and 3,504 control subjects from 31 separate data sets, and they investigated volume asymmetries of eight subcortical structures in 2,540 individuals with major depression and 4,230 control subjects from 32 data sets. T1-weighted MRI data were processed with a single protocol using FreeSurfer and the Desikan-Killiany atlas. The large sample size provided 80% power to detect effects of the order of Cohen's d=0.1. RESULTS: The largest effect size (Cohen's d) of major depression diagnosis was 0.085 for the thickness asymmetry of the superior temporal cortex, which was not significant after adjustment for multiple testing. Asymmetry measures were not significantly associated with medication use, acute compared with remitted status, first episode compared with recurrent status, or age at onset. CONCLUSIONS: Altered brain macro-anatomical asymmetry may be of little relevance to major depression etiology in most cases.
引用
- de Kovel CGF, Aftanas L, Aleman A, et al. No Alterations of Brain Structural Asymmetry in Major Depressive Disorder: An ENIGMA Consortium Analysis. Am J Psychiatry. 2019. PMID: 31352813. doi:10.1176/appi.ajp.2019.18101144
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。