文献速递精神分裂症与精神病性障碍心境障碍儿童青少年精神

精神分裂症、双相障碍与孤独症谱系障碍听觉稳态反应的系统综述与荟萃分析

A systematic review and meta-analysis of the auditory steady-state response in schizophrenia, bipolar disorder, and autism spectrum disorder.
PubMed 文献 · Mol Psychiatry · 2026-02-03

该系统综述与荟萃分析纳入52项研究,比较精神分裂症、双相障碍和孤独症谱系障碍患者及高危人群、患者一级亲属与健康对照在20Hz、40Hz和80Hz听觉稳态反应上的差异。结果显示精神分裂症、双相障碍和孤独症谱系障碍均存在40Hz听觉稳态反应功率降低,精神分裂症和双相障碍还存在40Hz试次间相位一致性降低,而20Hz和80Hz的缺陷可能为精神分裂症所特有。

要点

  • 40Hz听觉稳态反应功率降低见于精神分裂症、双相障碍和孤独症谱系障碍,支持其作为精神病性障碍潜在生物标志物。
  • 精神分裂症和双相障碍患者40Hz试次间相位一致性降低,患者一级亲属也见降低,但临床高危者未见。
  • 80Hz功率降低和20Hz试次间相位一致性降低仅见于精神分裂症,可能反映疾病特异性神经功能异常。

核心结论

  • 40Hz听觉稳态反应是精神病性障碍的潜在生物标志物,而20Hz和80Hz的缺陷可能为精神分裂症所特有。

研究设计与样本

  • 系统综述与荟萃分析,检索PubMed及参考文献至2025年1月,纳入52项研究。
  • 样本包括2116例精神分裂症患者、271例临床高危精神病个体、110例精神分裂症患者一级亲属、294例双相障碍患者、117例孤独症谱系障碍患者和2758名健康对照。

主要发现

  • 与健康对照相比,精神分裂症、双相障碍和孤独症谱系障碍均存在40Hz听觉稳态反应功率降低。
  • 精神分裂症和双相障碍患者40Hz试次间相位一致性降低,精神分裂症患者一级亲属也见40Hz功率和试次间相位一致性降低,但临床高危个体未见。
  • 精神分裂症患者80Hz听觉稳态反应功率降低,且20Hz试次间相位一致性降低,而双相障碍患者20Hz试次间相位一致性未见降低。

临床怎么用

  • 40Hz听觉稳态反应可作为跨诊断的精神病性障碍神经生理标志物,辅助区分精神分裂症与双相障碍及孤独症谱系障碍。
  • 20Hz和80Hz听觉稳态反应缺陷可能提示精神分裂症特异性神经功能异常,但需进一步研究确认。

局限性

  • 需进一步研究确认上述结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The 40-Hz auditory steady-state response (ASSR) is a potential biomarker for schizophrenia (SZ), bipolar disorder (BD), and autism spectrum disorder (ASD). However, the specific differences in ASSR across these disorders remain unclear. Moreover, the neurophysiological characteristics of the stimulation frequency in ASSR have not been fully elucidated. Hence, we conducted meta-analyses to comprehensively analyze 20-Hz, 40-Hz, and 80-Hz ASSR in individuals with SZ, BD, and ASD. METHODS: We included the studies published until January 2025, identified through a literature search in PubMed and the reference lists of relevant studies. We analyzed 52 studies, including 2116 patients with SZ, 271 individuals at clinical high-risk for psychosis (CHR-P), 110 first-degree relatives of patients with SZ (FDR-SZ), 294 patients with BD, 117 patients with ASD, and 2758 healthy controls (HC). RESULTS: The analyses indicated pronounced reductions in power and inter-trial phase coherence (ITPC) of 40-Hz ASSR in SZ, BD, and power reduction in ASD compared with HC. In addition, reduced power and ITPC were also observed in 40-Hz ASSR in FDR-SZ but not in CHR-P. Power reductions in 80-Hz ASSR were noted in individuals with SZ, while ITPC of 20-Hz ASSR was reduced in the SZ group but not in the BD group. CONCLUSIONS: These findings indicate that 40-Hz ASSR serves as a potential biomarker for psychotic disorders, whereas deficits at 20 Hz and 80 Hz may be specific to schizophrenia, reflecting distinct neural dysfunctions across diagnostic categories. Further studies are warranted to confirm these results.

来源:Mol Psychiatry,查看原文。版权归原作者所有。

引用

  1. Kinjo M, Tamura S, Sugiyama S, et al. A systematic review and meta-analysis of the auditory steady-state response in schizophrenia, bipolar disorder, and autism spectrum disorder. Mol Psychiatry. 2026. PMID: 41634135. doi:10.1038/s41380-026-03452-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。