DIEP皮瓣浅层减薄技术:肥胖患者美学乳房再造的安全选择
本研究先通过血管造影CT研究10例DIEP皮瓣的血管解剖,发现恒定的筋膜上穿支分支,并据此开发浅层减薄技术,前瞻性用于21例高BMI患者的乳房再造。7年回顾性分析(n=164)显示BMI与并发症无显著相关,仅上极阶梯畸形与BMI增加相关(p=0.001);浅层减薄组与回顾性高BMI组并发症无显著差异,但避免阶梯畸形方面有高度提示性差异(p=0.061)。结论认为浅层DIEP减薄是安全技术,便于皮瓣嵌入并改善肥胖患者乳房轮廓。
要点
- DIEP皮瓣存在恒定的筋膜上穿支分支,可作为浅层减薄技术的血管蒂。
- 浅层减薄技术用于21例高BMI患者,并发症与既往高BMI组无显著差异。
- 上极阶梯畸形与BMI增加相关(p=0.001),浅层减薄可能避免该畸形(p=0.061)。
核心结论
- 恒定的筋膜上穿支分支使浅层DIEP减薄成为安全技术,便于皮瓣嵌入并改善肥胖患者乳房轮廓。
研究设计与样本
- 先对10例DIEP皮瓣进行血管造影CT解剖研究,再前瞻性实施21例乳房再造,并与7年回顾性分析(n=164)比较。
主要发现
- 所有研究样本均显示主穿支的筋膜上分支,识别出两条恒定分支,其中一条走行于Scarpa筋膜表面并与皮下及真皮下血管丛形成丰富网络。
- 7年回顾性分析(n=164)显示BMI与并发症发生率无显著相关,仅长期上极阶梯畸形与BMI增加相关(p=0.001)。
- 回顾性高BMI组(n=72)与浅层减薄组并发症无统计学显著差异,但避免阶梯畸形方面有高度提示性差异(p=0.061)。
关键数值与推荐
- 浅层减薄技术依赖恒定的筋膜上血管作为剩余深层脂肪的血管蒂。
- 证据等级为治疗性IV级。
临床怎么用
- 对肥胖患者行DIEP乳房再造时,可采用浅层减薄技术以简化皮瓣嵌入并改善乳房轮廓。
局限性
- 原文未报告
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Abdominal flap-based breast reconstruction is challenging in the overweight and obese population not only because of increased donor-site complications, but also because excessive flap thickness makes inset cumbersome, requiring thinning and remodeling that frequently result in aesthetically poor outcomes. METHODS: The authors started by studying 10 deep inferior epigastric artery perforator flaps with angiographic computed tomography. Then, they prospectively performed 21 breast reconstructions using a superficial thinning technique reliant on a constant suprafascial vessel as the pedicle for the remaining deep fat and compared the rate of complications with their previous experience using traditional flap thinning techniques. RESULTS: All samples studied showed a suprafascial division of the main perforator. Two constant branches were identified, one coursing over the Scarpa fascia and displaying a robust network of linking vessels with the subcutaneous and subdermal plexuses. That anatomical insight was used to develop a flap-thinning technique tested on 21 consecutive high-body mass index patients. A 7-year retrospective analysis (n = 164) showed no significant correlation between body mass index and incidence of complications except for a long-term upper pole step deformity that was associated with increasing body mass index (p = 0.001). No statistically significant difference in complications was found comparing high-body mass index patients from the retrospective group (n = 72) with the superficial thinning group, but a highly suggestive difference (p = 0.061) was found regarding the avoidance of the step deformity using the superficial thinning technique. CONCLUSION: The presence of a constant suprafascial perforator branch makes superficial DIEP thinning a safe technique that facilitates inset and improves the reconstructed breast contour of obese patients. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.
引用
- De la Parra-Marquez M, Fernandez-Riera R, Romay-Chambers E, et al. Superficial Thinning of the DIEP Flap: A Safe Option to Achieve an Aesthetic Reconstructed Breast in the Obese Patient. Plast Reconstr Surg. 2021. PMID: 34705771. doi:10.1097/PRS.0000000000008481
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。