补片放置层次不影响显微乳房重建供区并发症
该回顾性研究纳入312例接受MS-TRAM或DIEP皮瓣自体乳房重建并供区植入聚丙烯补片的患者,比较补片置于overlay、inlay+overlay(I-O)及sublay三种层次下的供区并发症。结果显示不同补片层次间供区并发症发生率(P=0.68)及腹疝发生率(P=0.69)均无显著差异,多因素回归亦未发现补片位置与疝或伤口并发症显著相关。
要点
- 补片置于overlay、I-O或sublay对供区并发症无显著影响。
- MS-TRAM与DIEP术后腹疝发生率分别为2.86%与2.63%。
- 多因素回归未发现补片位置与疝或伤口并发症显著相关。
核心结论
- 合成补片相对于腹直肌的放置层次不影响MS-TRAM或DIEP乳房重建患者的供区术后并发症发生率。
研究设计与样本
- 回顾性分析312例接受MS-TRAM或DIEP皮瓣自体乳房重建并于供区植入聚丙烯补片的患者。
- 按补片位置分为overlay(n=90)、inlay+overlay(I-O;n=134)和sublay(n=88)三组进行比较。
主要发现
- MS-TRAM重建患者腹疝发生率为2.86%,DIEP重建患者为2.63%。
- overlay、I-O和sublay组供区并发症发生率分别为14.4%、13.4%和10.2%(P=0.68)。
- overlay、I-O和sublay组腹疝发生率分别为4.44%、2.24%和2.27%(P=0.69)。
- 多因素logistic回归分析未发现补片位置与疝率及伤口并发症之间存在显著关联。
临床怎么用
- 在MS-TRAM或DIEP乳房重建供区使用聚丙烯补片时,补片放置层次可根据术者习惯选择,不必因担心供区并发症而刻意改变层次。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Reinforcement of the abdominal wall with synthetic mesh in autologous breast reconstruction using abdominal free tissue transfer decreases the risk of bulging and herniation. However, the impact of the plane of mesh placement on donor site complications has not yet been investigated. METHODS: We performed a retrospective analysis of 312 patients who had undergone autologous breast reconstruction with muscle-sparing transverse rectus abdominis myocutaneous (MS-TRAM) flaps or deep inferior epigastric perforator (DIEP) flaps as well as polypropylene mesh implantation at the donor site. Donor site complications were compared among patients with different flap types and different mesh positions including overlay (n = 90), inlay and overlay (I-O; n = 134), and sublay (n = 88). RESULTS: Abdominal hernias occurred in 2.86% of patients who had undergone MS-TRAM reconstructions and in 2.63% of patients who had undergone DIEP reconstructions. When comparing patients with different mesh positions, donor site complications occurred in 14.4% of patients with overlay mesh, 13.4% of patients with I-O mesh, and 10.2% of patients with sublay mesh (P = 0.68). Abdominal hernias occurred in 4.44% of patients with overlay mesh, 2.24% of patients with I-O mesh, and 2.27% of patients with sublay mesh (P = 0.69). Multivariable logistic regression analysis did not identify a significant association between mesh position and hernia rates as well as wound complications. CONCLUSIONS: Our data indicate that the plane of synthetic mesh placement in relation to the rectus abdominis muscle does not impact the rate of postoperative donor site complications in patients undergoing breast reconstruction with MS-TRAM or DIEP flaps.
引用
- Henn D, Sivaraj D, Barrera JA, et al. The Plane of Mesh Placement Does Not Impact Abdominal Donor Site Complications in Microsurgical Breast Reconstruction. Ann Plast Surg. 2021. PMID: 34699433. doi:10.1097/SAP.0000000000002897
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。