文献速递乳房整形与再造美容整形

Eurosilicone圆形微绒面乳房假体15-19年满意度与翻修率:单中心单医生经验

Single Center and Surgeon's Long-Term (15-19 Years) Patient Satisfaction and Revision Rate of Round Textured Eurosilicone Breast Implants.
PubMed 文献 · Aesthet Surg J · 2022-01-01

该回顾性队列研究纳入2001-2004年间84例接受Eurosilicone Cristalline Paragel圆形微绒面假体初次隆乳的患者,随访15-19年,采用BREAST-Q问卷评估满意度并分析翻修情况。结果显示BREAST-Q评分较高,总体翻修率为29.8%,双平面与腺体下置入组间无显著差异。

要点

  • 随访15-19年,患者满意度高,总体翻修率29.8%
  • 双平面与腺体下置入组满意度及翻修率无显著差异
  • 长期随访支持该假体的安全性与患者满意度

核心结论

  • 随访15-19年,Eurosilicone圆形微绒面假体隆乳患者满意度高且翻修率相对较低。
  • 双平面与腺体下置入在满意度和翻修率上无临床相关显著差异。

研究设计与样本

  • 单中心、单医生回顾性队列研究,纳入84例2001-2004年间初次隆乳患者。
  • 假体为Eurosilicone Cristalline Paragel圆形微绒面,置入层次为双平面或腺体下。
  • 通过BREAST-Q问卷评估患者满意度,并分析翻修原因包括包膜挛缩、破裂、疼痛和/或美学原因。

主要发现

  • BREAST-Q评分较高:连续变量(0-100分)为67%-100%,分类变量中66.0%-77.3%的患者评为「非常满意」。
  • 总体翻修率为29.8%,双平面与腺体下置入组间无显著差异(P=0.317)。
  • 双平面与腺体下置入组在BREAST-Q评分上无临床显著差异。

临床怎么用

  • 长期随访数据支持Eurosilicone圆形微绒面假体在隆乳中的应用。
  • 假体置入层次(双平面或腺体下)的选择可不影响长期满意度与翻修率。

局限性

  • 单中心、单医生经验,样本量84例,结果外推需谨慎。
  • 回顾性研究设计可能存在选择偏倚和信息偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Breast augmentation is one of the most commonly performed aesthetic plastic surgical procedures, with over 250,000 procedures in the United States in 2020 alone. However, the safety of breast implants should be closely researched and monitored, especially in the long term. OBJECTIVES: This study was undertaken to evaluate the long-term results of round micro-textured Eurosilicone (Eurosilicone S.A.S, Apt Cedex, France) Cristalline Paragel breast implants from a single-center, single-surgeon experience regarding both patient-reported outcome measures and revisions. METHODS: A retrospective cohort study was undertaken of 84 patients who underwent primary breast augmentation with round micro-textured Eurosilicone Cristalline Paragel breast implants, either submuscular (dual-plane) or subglandular placed, between 2001 and 2004. All patients were contacted for informed consent, and after approval, the validated BREAST-Q questionnaire was sent and utilized to analyze patient satisfaction. In addition, objective data regarding revisions, including capsular contracture, rupture rate, pain, and/or aesthetic causes needing revision surgery, were analyzed. RESULTS: High BREAST-Q scores (67%-100% for 0-100 scale variables and 66.0%-77.3% of the patients scored "very satisfied" on categorical variables) were found without clinically significant differences between patients with dual-plane-placed implants and subglandular-placed implants. The overall revision rate was 29.8%, also with no significant differences between groups (P = 0.317). CONCLUSIONS: This study showed high patient satisfaction and relatively low revision rates after 15 to 19 years of follow-up of round micro-textured Eurosilicone Cristalline Paragel breast implants. No clinically relevant significant differences were found between dual-plane and subglandular placement of the implants.

来源:Aesthet Surg J,查看原文。版权归原作者所有。

引用

  1. Kooiman L, Torensma B, Stevens H, et al. Single Center and Surgeon's Long-Term (15-19 Years) Patient Satisfaction and Revision Rate of Round Textured Eurosilicone Breast Implants. Aesthet Surg J. 2022. PMID: 34677578. doi:10.1093/asj/sjab373

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。