原发性乳房扩大整形术中乳房下皱襞的新分类
结果显示双泡畸形发生率低于1%,且均见于F3型皱襞患者。该分类有助于选择合适的手术入路和假体尺寸规划。
要点
- 术前评估乳房下皱襞形态对原发性乳房扩大整形术的手术规划至关重要。
- 新分类将乳房下皱襞分为F0(不存在)至F3(成形且固定)四种亚型。
- 双泡畸形发生率低于1%,且全部发生于F3型皱襞患者。
核心结论
- 乳房下皱襞是下极的美学边界和关键标志,新分类系统有助于选择皱襞处理方式和假体尺寸规划。
- 识别F3型乳房下皱襞可最小化皱襞相关并发症风险,在超过2000例中验证。
研究设计与样本
- 基于标准化术前照片回顾,制定乳房下皱襞形态新分类,术后每3个月进行结局评估。
主要发现
- 根据临床外观识别出四种乳房下皱襞亚型:从不存在型F0到成形且固定型F3。
- 主要结局指标为术后双泡畸形,队列中共识别3例(低于1%的患者)。
- 所有双泡畸形病例均发生于F3型皱襞患者。
关键数值与推荐
- 双泡畸形发生率低于1%(3例/2192例)。
- 证据等级:治疗性,IV级。
临床怎么用
- 术前应评估原生乳房下皱襞解剖并分型,以指导手术规划和假体尺寸选择。
- 对F3型皱襞患者需特别注意皱襞处理,以降低双泡畸形等并发症风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Previous aesthetic breast surgery algorithms have not addressed the importance of evaluating the native inframammary fold before primary breast augmentation. In the authors' experience, assessment of native inframammary fold anatomy significantly impacts surgical planning and technique. Failure to adequately evaluate and manage the inframammary fold leads to many of the common problems of the lower pole, including double-bubble deformity. METHODS: The authors assessed the inframammary fold preoperatively in 2192 consecutive patients undergoing primary breast augmentation between June of 2014 and December of 2018. A novel classification of inframammary fold morphology was devised based on review of standardized preoperative photographs. Outcome assessment was performed postoperatively at 3-month intervals. RESULTS: The authors identified four clear inframammary fold subtypes based on their clinical appearance, ranging from the nonexistent type F0 to the well-formed and fixed type F3. The key outcome measure examined was the presence of double-bubble deformity postoperatively. There were three total cases of double-bubble deformity identified in our cohort (<1 percent of patients). All cases of double-bubble deformity occurred in patients with a type 3 fold. CONCLUSIONS: The inframammary fold defines the inferior boundary of the lower pole of the breast and is a critical landmark to the aesthetic breast surgeon. The authors describe a unique and simple inframammary fold classification system that assists in selection of the appropriate approach to the inframammary fold in addition to implant dimensional planning. The authors have found that this system-in particular, the identification of the type F3 inframammary fold-has minimized the risk of inframammary fold-associated complications in over 2000 cases. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.
引用
- Phillips NA, Millan LS, Miroshnik M, et al. A Novel Classification of the Inframammary Fold for Use in Primary Breast Augmentation. Plast Reconstr Surg. 2021. PMID: 34644274. doi:10.1097/PRS.0000000000008563
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。