文献速递乳房整形与再造显微修复重建

吲哚菁绿血管造影对DIEP皮瓣乳房再造术后脂肪坏死的影响

The Impact of Indocyanine Green Angiography on Fat Necrosis in Deep Inferior Epigastric Perforator Flap Breast Reconstruction.
PubMed 文献 · Ann Plast Surg · 2022-01-01

结果显示ICGA组与非ICGA组可手术脂肪坏死发生率无统计学差异(P=0.732),但脂肪坏死与BMI持续相关(P=0.001)及BMI>35时相关(P=0.038)。

要点

  • ICGA术中评估并未降低DIEP皮瓣可手术脂肪坏死的发生率。
  • 脂肪坏死发生率与BMI作为连续变量及BMI>35均呈显著相关。

核心结论

  • 回顾性分析未显示ICGA降低DIEP皮瓣可手术脂肪坏死的发生率。
  • 脂肪坏死发生率与BMI(作为连续变量及>35分类)显著相关。

研究设计与样本

  • ICGA采用静脉注射,以相对和绝对值荧光单位量化,相对值低于25%–30%的组织予以切除。

主要发现

  • ICGA组与非ICGA组术后脂肪坏死发生率无统计学显著差异(P=0.732)。
  • 脂肪坏死与BMI作为连续变量相关(P=0.001),与BMI>35分类亦相关(P=0.038)。

关键数值与推荐

  • ICGA评估中相对荧光值低于25%–30%的组织被切除。
  • 脂肪坏死与BMI连续变量相关P=0.001,BMI>35分类相关P=0.038。

临床怎么用

  • ICGA虽可用于多种整形手术,但本研究未支持其降低DIEP皮瓣可手术脂肪坏死。
  • BMI较高的DIEP皮瓣患者脂肪坏死风险更高,需加强关注。

局限性

  • 原文未报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The deep inferior epigastric perforator flap (DIEP) is a widely known reliable option for autologous breast reconstruction. One common complication of DIEP procedures is fat necrosis. Consequences of fat necrosis include wound healing complications, pain, infection, and the psychological distress of possible cancerous recurrence. Clinical judgment alone is an imperfect method to detect at-risk segments of adipose tissue. Objective methods to assess perfusion may improve fat necrosis complication rates, reducing additional surgeries to exclude cancer and improve cosmesis for patients. METHODS: The authors performed a retrospective review of patients who underwent analysis of DIEP flap vascularity with or without intraoperative indocyanine green angiography (ICGA). Flap perfusion was assessed using intravenous ICGA and was quantified with both relative and absolute value units of fluorescence. Tissue with observed values less than 25% to 30% relative value units was resected. Postoperative outcomes and fat necrosis incidence were collected. RESULTS: Three hundred fifty-five DIEP flaps were included in the study, 187 (52.7%) of which were assessed intraoperatively with ICGA. Thirty-nine patients (10.9%) experienced operable fat necrosis. No statistically significant difference in incidence of postoperative fat necrosis was found between the 2 groups (P = 0.732). However, a statistically significant relationship was found between fat necrosis incidence and body mass index as both a continuum (P = 0.001) and when categorized as greater than 35 (P = 0.038). CONCLUSIONS: Although ICGA is useful for a variety of plastic surgery procedures, our retrospective review did not show a reduction in operable fat necrosis when using this technology.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Yoo A, Palines PA, Mayo JL, et al. The Impact of Indocyanine Green Angiography on Fat Necrosis in Deep Inferior Epigastric Perforator Flap Breast Reconstruction. Ann Plast Surg. 2022. PMID: 34611093. doi:10.1097/SAP.0000000000003021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。