高光谱成像在前瞻性单中心研究中评估烧伤深度
该前瞻性单中心研究纳入59例热烧伤患者,在伤后24、48、72小时进行高光谱成像(HSI)并计算HSI烧伤指数(BI),比较21天内二次愈合组(A组)与需植皮或愈合超过21天组(B组)。结果显示两组各时间点BI均有显著差异,伤后72小时BI预测植皮需求的敏感度为92%、特异度为71%。
要点
- HSI烧伤指数在伤后24、48、72小时均能区分愈合时间≤21天与>21天或需植皮的患者。
- 伤后72小时BI预测植皮需求:阈值1.27,敏感度92%,特异度71%。
- HSI可反映热烧伤后72小时内微循环变化,辅助烧伤深度评估。
核心结论
- 热烧伤后72小时内两组BI均升高,反映微循环变化。
- 伤后72小时BI可预测植皮需求,敏感度92%、特异度71%。
研究设计与样本
- 纳入标准:年龄≥18岁、二度或三度热烧伤、签署知情同意、伤后24小时内就诊。
- 伤后24、48、72小时进行临床评估和HSI,比较21天内二次愈合组(A组,36例)与需植皮或愈合超过21天组(B组,13例)。
主要发现
- A组平均年龄41.5岁、平均烧伤体表面积2.7%;B组平均年龄46.8岁、平均烧伤体表面积4.0%。
- 伤后24、48、72小时BI:A组分别为1.0±0.28、1.2±0.29、1.55±0.27;B组分别为0.78±0.14、1.05±0.23、1.23±0.27。
- 各时间点两组BI差异均有统计学意义(P<0.05)。
- ROC分析:24小时BI阈值0.95(敏感度0.61/特异度1.0),48小时阈值1.17(敏感度0.51/特异度0.81),72小时阈值1.27(敏感度0.92/特异度0.71)。
关键数值与推荐
- BI由HSI生成参数组合而成,用于预测植皮需求。
- 伤后72小时BI阈值1.27时,预测植皮需求的敏感度92%、特异度71%。
临床怎么用
- HSI可在伤后72小时内无创评估烧伤深度,辅助判断是否需要植皮。
- 伤后72小时BI阈值1.27可作为预测植皮需求的参考指标。
局限性
- 10例因数据质量差被排除。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The assessment of thermal burn depth remains challenging. Over the last decades, several optical systems were developed to determine burn depth. So far, only laser doppler imaging (LDI) has been shown to be reliable while others such as infrared thermography or spectrophotometric intracutaneous analysis have been less accurate. The aim of our study is to evaluate hyperspectral imaging (HSI) as a new optical device. METHODS: Patients suffering thermal trauma treated in a burn unit in Germany between November 2019 and September 2020 were included. Inclusion criteria were age ≥18 years, 2nd or 3rd degree thermal burns, written informed consent and presentation within 24 h after injury. Clinical assessment and hyperspectral imaging were performed 24, 48 and 72 h after the injury. Patients in whom secondary wound closure was complete within 21 days (group A) were compared to patients in whom secondary wound closure took more than 21 days or where skin grafting was indicated (group B). Demographic data and the primary parameters generated by HSI were documented. A Mann Whitney-U test was performed to compare the groups. A p-value below 0.05 was considered to be statistically significant. The data generated using HSI were combined to create the HSI burn index (BI). Using a logistic regression and receiver operating characteristics curve (ROC) sensitivity and specificity of the BI were calculated. The trial was officially registered on DRKS (registration number: DRKS00022843). RESULTS: Overall, 59 patients with burn wounds were eligible for inclusion. Ten patients were excluded because of a poor data quality. Group A comprised 36 patients with a mean age of 41.5 years and a mean burnt body surface area of 2.7%. In comparison, 13 patients were allocated to group B because of the need for a skin graft (n = 10) or protracted secondary wound closure lasting more than 21 days. The mean age of these patients was 46.8 years. They had a mean affected body surface area of 4.0%. 24, 48, and 72 h after trauma the BI was 1.0 ± 0.28, 1.2 ± 0.29 and 1.55 ± 0.27 in group A and 0.78 ± 0.14, 1.05 ± 0.23 and 1.23 ± 0.27 in group B. At every time point significant differences were demonstrated between the groups. At 24 h, ROC analysis demonstrated BI threshold of 0.95 (sensitivity 0.61/specificity 1.0), on the second day of 1.17 (sensitivity 0.51/specificity 0.81) and on the third day of 1.27 (sensitivity 0.92/specificity 0.71). CONCLUSION: Changes in microcirculation within the first 72 h after thermal trauma were reflected by an increasing BI in both groups. After 72 h, the BI is able to predict the need for a skin graft with a sensitivity of 92% and a specificity of 71%.
引用
- Schulz T, Marotz J, Seider S, et al. Burn depth assessment using hyperspectral imaging in a prospective single center study. Burns. 2021. PMID: 34702635. doi:10.1016/j.burns.2021.09.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。