DIEP皮瓣乳房再造中蒂长测量技术的随机对照研究
单中心开放标签随机对照试验纳入389例延迟乳房再造患者,比较常规DIEP皮瓣技术与蒂长测量技术。测量组术前确定皮瓣放置方式并测量受区血管与穿支入皮下点距离,使蒂长较该距离长1cm;测量组静脉淤血、脂肪坏死、部分及全部皮瓣坏死发生率均显著低于对照组。
要点
- 蒂长测量技术可显著降低DIEP皮瓣静脉淤血发生率(0.5% vs 8.3%)。
- 测量组全部皮瓣坏死为0%,对照组为3.3%。
- 测量组脂肪坏死和部分皮瓣坏死发生率也显著低于对照组。
核心结论
- DIEP皮瓣转移中测量蒂长是可靠技术,可保障皮瓣安全、减少手术创伤并显著降低并发症风险。
研究设计与样本
- 单中心、开放标签、前瞻性随机对照试验,共纳入389例接受延迟乳房再造的游离单蒂DIEP皮瓣患者,受区血管为胸廓内血管。
- 对照组180例采用常规DIEP皮瓣技术,全程游离蒂血管;测量组209例术前确定皮瓣放置方式,测量胸廓内血管与DIEP穿支入皮下点距离A,再测量并游离穿支和主干使长度B较A长1cm。
主要发现
- 静脉淤血在对照组发生15例(8.3%),测量组1例(0.5%)(P < 0.001);16例均发现静脉血栓,10例游离皮瓣挽救成功。
- 脂肪坏死在对照组16例(8.9%),测量组5例(2.4%)(P = 0.006)。
- 部分皮瓣坏死在对照组12例(6.7%),测量组3例(1.4%)(P = 0.008)。
- 全部皮瓣坏死在对照组6例(3.3%),测量组0例(0%)(P = 0.009)。
临床怎么用
- 在DIEP皮瓣乳房再造中,术前确定皮瓣放置方式并测量受区血管与穿支入皮下点距离A,按穿支和主干长度较A长1cm进行游离,可降低静脉淤血和皮瓣坏死风险。
局限性
- 单中心、开放标签设计可能引入偏倚;摘要未报告盲法、随访时长及除静脉血栓外的其他混杂因素。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Intraoperative venous congestion is a main complication in deep inferior epigastric artery perforator (DIEP) flap for breast reconstruction. We present a pedicle measuring technique to precisely predict the length of pedicle needed in DIEP free flap, to improve the outcome, and to reduce the risk of donor site morbidity and complications. MATERIALS AND METHODS: A single-center, open-label, prospective, randomized study was carried out to access efficacy and safety of a pedicle measuring technique in 389 patients. Each patient received a delayed breast reconstruction using free unipedicled DIEP flap, and internal mammary vessels were chosen as recipient vessels. During the surgery, the conventional DIEP flap technique was used in the control group, in which the course of the pedicle was fully dissected. In the measuring group, the flap in setting way was decided preoperatively, the distance (A) between the internal mammary vessels (a) and the point of DIEP perforator into the subcutaneous tissue (b) was measured, and then the length (B) of the perforator (c) and the main trunk (d) is measured and dissected to achieve 1 cm longer than A. RESULTS: There are 180 and 209 patients enrolled in the control and measuring group, respectively. Venous congestion occurred in 15 patients (8.3%) in the control group, and 1 patient (0.5%) in the measuring group ( P < 0.001). All the 16 patients were found venous thrombosis. Then successful free flap salvage surgeries were performed in 10 patients. Six patients (3.3%) had total flap necrosis due to recurrent venous thromboembolisms. Fat necrosis occurred in 16 patients (8.9%) in the control group, and 5 patients (2.4%) in the measuring group ( P = 0.006). Partial flap necrosis was found in 12 patients (6.7%) in the control group, and in 3 patients (1.4%) in the measuring group ( P = 0.008). Total flap necrosis occurred in 6 patients (3.3%) in the control group, but no (0%) patient in the measuring group ( P = 0.009). CONCLUSIONS: Measurement of pedicle length for DIEP flap transferring in breast reconstruction is a reliable technique that could secure the DIEP free flap, reduce operative invasiveness, and lower the risk of complications considerably.
引用
- Song D, Pafitanis G, Li J, et al. The Role of Measurement of Pedicle Length for DIEP Flap Transferring in Breast Reconstruction: A Single-Center, Open-Label, Randomized Controlled Trial. Ann Plast Surg. 2021. PMID: 34510077. doi:10.1097/SAP.0000000000002978
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。