文献速递显微修复重建创面修复

游离组织移植端侧吻合后受区动脉的长期通畅性与流体动力学

Long-Term Patency and Fluid Dynamics of Recipient Artery after End-to-Side Anastomosis for Free Tissue Transfer.
PubMed 文献 · Plast Reconstr Surg · 2021-01-01

本研究纳入15例2003至2017年间接受肢体游离皮瓣端侧吻合至非关键血管的患者,评估吻合口远端受区动脉的通畅性及流体动力学参数。结果显示远端血流存在率为93%(14/15),吻合血管与侧支血管的阻力指数无统计学差异,吻合血管下游体积流量与非手术对侧肢体同血管相似,雷诺数远低于湍流阈值。

要点

  • 端侧吻合至非关键血管的长期通畅率为93%(14/15)。
  • 吻合血管与侧支血管阻力指数无统计学差异(0.859±0.300 vs 0.853±0.179)。
  • 吻合血管下游体积流量与非手术对侧同血管相似(139±92.0 vs 137±41.6 cm3/min)。

核心结论

  • 端侧吻合至非关键血管可获得93%的长期受区血管通畅率,且通畅血管的体积流量、阻力指数及流体动力学无统计学显著变化。

研究设计与样本

  • 回顾性纳入15例2003至2017年间接受肢体游离皮瓣端侧吻合至非关键血管的成功病例,采用体积描记和双功超声评估吻合口远端受区动脉通畅性,并与同侧侧支血管及非手术对侧肢体血管进行配对t检验比较。

主要发现

  • 15例中14例(93%)检测到下游血流。
  • 吻合血管阻力指数为0.859±0.300,同侧侧支血管为0.853±0.179,无统计学差异。
  • 吻合血管下游体积流量为139±92.0 cm3/min,非手术对侧同血管为137±41.6 cm3/min。
  • 吻合血管雷诺数为448±202,非手术对侧为493±127,均远低于湍流阈值。

临床怎么用

  • 端侧吻合至非关键血管可维持受区动脉远端长期通畅,术后可通过超声评估下游血流及流体动力学参数。

局限性

  • 样本量较小(15例),为单中心回顾性设计,仅纳入肢体游离皮瓣且吻合至非关键血管的病例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: End-to-end microvascular anastomoses sacrifice downstream inline perfusion of the recipient vessels. End-to-side anastomoses, in theory, maintain distal inline flow of the recipient vessel. The proposed benefit of the end-to-side technique depends on patency of the distal vessels and subsequent flow parameters, but maintenance of distal perfusion has not been conclusively demonstrated. METHODS: Fifteen patients who underwent a successful extremity free flap procedure via end-to-side anastomoses to a noncritical vessel between 2003 and 2017 were enrolled. Recipient artery patency distal to the anastomosis was assessed using pulse volume recordings and duplex ultrasound imaging. Resistance indices, flow velocities, vessel diameters, volumetric flow, and turbulent flow dimensionless number (Reynolds number) were measured. Comparisons were made to the ipsilateral collateral vessel as well as to the vessels on the nonoperative contralateral limb using paired t tests. RESULTS: Downstream flow was identified in 14 of 15 patients (93 percent patency). There was no statistical difference in resistive indices comparing the anastomotic vessel (0.859 ± 0.300) and the collateral vessel (0.853 ± 0.179) of the ipsilateral extremity. Ultrasound flows were similar; the anastomotic vessel demonstrated downstream volumetric flows of 139 ± 92.0 cm3/min versus 137 ± 41.6 cm3/min within the same vessel of the nonoperative contralateral limb. The anastomotic vessel had Reynolds numbers well below the turbulent threshold (448 ± 202 and 493 ± 127 for the anastomotic and nonoperative contralateral limb, respectively). CONCLUSION: End-to-side anastomosis to noncritical vessels resulted in a 93 percent long-term recipient vessel patency rate, with no statistically significant changes in volumetric flows, resistive indices, or fluid dynamics in the vessels that remained patent.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Treiser MD, Miles MR, Albino FP, et al. Long-Term Patency and Fluid Dynamics of Recipient Artery after End-to-Side Anastomosis for Free Tissue Transfer. Plast Reconstr Surg. 2021. PMID: 34586089. doi:10.1097/PRS.0000000000008439

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。