目标导向凝血管理减少严重烧伤患者血制品使用
该回顾性队列研究纳入苏黎世大学医院烧伤中心 20-80% 体表面积严重烧伤的成人患者,比较引入目标导向凝血算法前后两个三年期间血制品使用和临床结局。结果显示算法组每患者红细胞减少 33 单位、新鲜冰冻血浆减少 9 单位、纤维蛋白原减少 1.4g,感染和死亡率无显著差异。
要点
- 目标导向凝血算法可显著减少严重烧伤患者红细胞、血浆和纤维蛋白原用量。
- 算法组感染率 41.5% 低于对照组 61.8%,死亡率 26.8% 低于 38.9%,但差异无统计学意义。
- 严重烧伤患者应优先采用目标导向凝血管理以优化血制品使用。
核心结论
- 对严重烧伤患者采用目标导向凝血算法可减少血制品使用,并实现凝血因子的目标导向给药以改善结局。
研究设计与样本
- 回顾性队列研究,纳入苏黎世大学医院烧伤中心 20-80% 体表面积严重烧伤的成人患者,比较算法引入前(2009-2011 年,36 例)与引入后(2016-2018 年,42 例)两个三年期间。
主要发现
- 算法组每患者红细胞减少 33 单位(95%CI -52.8 至 -12.9,p=0.002)。
- 算法组每患者新鲜冰冻血浆减少 9 单位(95%CI -14.7 至 -2.6,p=0.006)。
- 算法组每患者纤维蛋白原减少 1.4g(95%CI -2.2 至 -0.5,p=0.001)。
- 感染率 61.8% 对 41.5%(p=0.11),死亡率 38.9% 对 26.8%(p=0.33),差异均无统计学意义。
临床怎么用
- 对严重烧伤患者可考虑实施目标导向凝血算法以减少血制品输注。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Transfusion of allogenic blood products was shown to be associated with more adverse events and a higher mortality in severely burned patients. This study investigated the impact of a goal-directed and factor-based coagulation algorithm on blood product use and clinical outcomes in severely burned patients. METHODS: This retrospective cohort study included adult patients admitted to the burn center of the University Hospital Zurich with major burn injuries compromising 20-80% of total body surface area. We compared two 3-year periods, one before the introduction of a goal-directed coagulation and transfusion algorithm (period 1: 2009-2011) and one after (period 2: 2016-2018). We applied linear and logistic regression models adjusted for confounders. RESULTS: We analyzed 36 patients (27.8% female) versus 42 patients (14.3% female) in period 1 and 2, respectively. Comorbidities and burn types were comparable between both collectives. Treatment according to the coagulation algorithm resulted in an overall reduction of 33 units of red blood cells (95% CI -52.8 to -12.9, p = 0.002), 9 units fresh frozen plasma (95% CI -14.7 to -2.6, p = 0.006) and 1.4g fibrinogen (95% CI -2.2 to -0.5, p = 0.001) per patient. We observed less infections (61.8% vs. 41.5%, p = 0.11) and a reduced mortality (38.9% vs. 26.8%, p = 0.33) during the algorithm treated period, although not significant. CONCLUSION: Treatment of severely burned patients with a goal-directed coagulation algorithm reduced blood product use and resulted in target-oriented administration of coagulation factors to improve outcomes.
引用
- Sahli SD, Pedrazzi N, Braun J, et al. Effect of a factor-based coagulation management on blood product use after major burn injury: A retrospective cohort study. Burns. 2021. PMID: 34465509. doi:10.1016/j.burns.2021.08.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。