游离皮瓣血流贯通式动脉吻合增加血流量与降低血管阻力的前瞻性定量评价
贯通式吻合时容积流量显著增加(18.9±14.1 vs 6.0±6.3 ml/min),搏动指数显著降低(5.2±3.7 vs 13.6±10.2)。作者认为贯通式动脉吻合在血流与血管阻力方面具有定量优势,供受区血管条件满足时应予采用。
要点
- 贯通式动脉吻合较端端吻合显著提高皮瓣血流入量并降低血管阻力。
- 穿支皮瓣(较肌皮瓣)与端端吻合时血流量降低、搏动指数升高独立相关。
- 高血压与端端吻合时搏动指数升高独立相关。
核心结论
- 血流贯通式动脉吻合在血流量和血管阻力方面具有可量化的良好效果,供受区血管条件满足时应予实施。
研究设计与样本
- 先于端端吻合状态下测量近端吻合口,再开放远端动脉夹后继续测量贯通状态。
- 证据等级为治疗性IV级。
主要发现
- 贯通式吻合较端端吻合容积流量显著增加(18.9±14.1 ml/min 对 6.0±6.3 ml/min,配对比较)。
- 贯通式吻合较端端吻合搏动指数显著降低(5.2±3.7 对 13.6±10.2,配对比较)。
- 多因素回归显示穿支皮瓣(较肌皮瓣)与端端吻合时容积流量降低及搏动指数升高独立相关。
- 多因素回归显示高血压与端端吻合时搏动指数升高独立相关。
- 贯通式吻合状态下上述指标均无显著相关因素。
临床怎么用
- 在供受区血管条件满足要求时,可优先考虑血流贯通式动脉吻合以增加皮瓣灌注。
- 对穿支皮瓣或合并高血压患者,端端吻合时需更关注血流量与血管阻力变化。
局限性
- 证据等级为治疗性IV级,非随机对照设计。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The clinical application of flow-through anastomosis has been reported in various studies; however, no studies have quantitatively evaluated and compared the actual hemodynamics in flow-through anastomosis and end-to-end anastomosis. This study quantitatively evaluated the blood inflow (volumetric flow rate) and vascular resistance (pulsatility index) of flow-through arterial anastomosis using an ultrasonic flowmeter, and compared these values with those of end-to-end anastomosis in actual clinical settings. In addition, factors affecting the outcomes have also been examined. METHODS: Twenty-eight patients who underwent free flap reconstruction after tumor resection were subjected to flow-through arterial anastomosis and flow examination. First, in the end-to-end state, the proximal anastomotic site was measured. This was followed by the opening of the distal arterial clamp, and measurement was then continued (in the flow-through state). RESULTS: In flow-through arterial anastomosis compared with end-to-end anastomosis, the volumetric flow rate was significantly increased (18.9 ± 14.1 ml/minute versus 6.0 ± 6.3 ml/minute) and the pulsatility index was significantly decreased (5.2 ± 3.7 versus 13.6 ± 10.2), when comparing paired data. Multiple regression analyses revealed that a perforator flap (versus a musculocutaneous flap) was independently associated with both reduced volumetric flow rate and increased pulsatility index in end-to-end anastomosis, and that hypertension was independently associated with an increased pulsatility index in end-to-end anastomosis. However, no factors in flow-through anastomosis were significantly associated with those values. CONCLUSION: In terms of blood flow and vascular resistance, flow-through arterial anastomosis was considered to have promising quantitative effects and should be performed when the conditions of both the donor and recipient vessels meet the requirements. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.
引用
- Kagaya Y, Arikawa M, Akazawa S, et al. A Quantitative Evaluation of the Flow-Increasing Effect of Flow-Through Arterial Anastomosis in the Vascular Pedicle of Free Flaps: A Prospective Clinical Before-and-After Study. Plast Reconstr Surg. 2021. PMID: 34415882. doi:10.1097/PRS.0000000000008354
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。