文献速递显微修复重建创面修复

温敏泊洛沙姆联合氰基丙烯酸酯无缝合静脉显微吻合的大鼠实验研究

Sutureless venous microanastomosis using thermosensitive poloxamer and cyanoacrylate: experimental study on a rat model.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2021-06-17

在大鼠模型中比较温敏泊洛沙姆(TP407)联合氰基丙烯酸酯无缝合静脉吻合与传统手工缝合的效果。无缝合组吻合时间显著短于对照组,但即刻和15天通畅率略低。该方法可行且快速,但需在大动物长期随访中进一步验证。

要点

  • TP407联合氰基丙烯酸酯可实现快速无缝合静脉吻合。
  • 无缝合组吻合时间11.9±1.37分钟,对照组27.75±3.31分钟。
  • 无缝合组15天通畅率85%,对照组90%,需大动物长期验证。

核心结论

  • TP407联合氰基丙烯酸酯可为静脉无缝合吻合提供快速可靠的技术。
  • 该方法在人体应用前仍需在大动物长期随访中确认有效性。

研究设计与样本

  • 大鼠模型实验,20只雄性Sprague-Dawley大鼠,体重265–310 g。
  • 无缝合组行20条左颈外静脉端端吻合,对照组行20条右颈外静脉10-0缝线吻合。

主要发现

  • 左颈外静脉平均直径0.94±0.1 mm,右颈外静脉0.95±0.09 mm。
  • 无缝合组平均吻合时间11.9±1.37分钟,对照组27.75±3.31分钟。
  • 对照组即刻通畅率95%,15天90%;无缝合组即刻90%,15天85%。

临床怎么用

  • 该技术可缩短静脉显微吻合操作时间,但通畅率略低于传统缝合,暂不宜直接用于临床。

局限性

  • 仅在大鼠模型中进行,样本量有限,缺乏大动物长期随访数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Sutureless microvascular anastomoses could simplify the microvascular field, shortening operative time and improving the final outcome. The use of thermosensitive poloxamers (TP407) together with the application of cyanoacrylate as an alternative method for conventional sutures was well-documented for arteries, but not for veins. The purpose of our study was to prove the feasibility of this technique for venous anastomoses and compare it with the traditional hand-sewn technique on a rat model. MATERIALS AND METHODS: Twenty male Sprague-Dawley rats that weighed between 265 and 310 g were used. In the sutureless group (SG), 20 left external jugular veins (LEJV) end-to-end anastomoses were performed using a T704 and cyanoacrylate glue. They were compared to 20 right external jugular veins (REJV) anastomoses sutured with conventional 10-0 stitches (control group - CG). Diameters of veins, anastomosis time, and patency rate at 15 days were reported. Foreign body reaction was assessed histologically. RESULTS: The mean diameter of the LEJV was 0.94 ± 0.1 mm and 0.95 ± 0.09 mm for the REJV. The mean anastomosis time was 11.9 ± 1.37 min for the SG and 27.75 ± 3.31 min for the CG. In the latter group, the immediate patency rate was 95% and 90% at 15 days. For the SG group, 90% of the anastomoses were patent immediately and 85% at 15 days. CONCLUSION: TP407 and cyanoacrylate could offer a fast and reliable technique for sutureless venous anastomoses. Before human application, effectiveness of this method remains to be confirmed in larger animals in a long-term follow-up.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Qassemyar Q, Michel G, Gianfermi M, et al. Sutureless venous microanastomosis using thermosensitive poloxamer and cyanoacrylate: experimental study on a rat model. J Plast Reconstr Aesthet Surg. 2021. PMID: 34247962. doi:10.1016/j.bjps.2021.05.072

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。