文献速递烧伤创面修复

澳新健康专业人员对手部烧伤后结局指标的临床视角调查

A Cross-sectional Survey of Health Professionals Across Australia and New Zealand to Determine What Outcome Measures Are Important From a Clinical Perspective Post Hand Burn Injury.
PubMed 文献 · J Burn Care Res · 2022-01-01

该横断面调查收集了43名澳大利亚和新西兰临床专科 allied health 专业人员对手部烧伤后结局测量工具的使用情况。受访者认为患者最重视手部灵活性,伤后3个月是最常见测量时间点(n=31,72.1%),患者报告手功能(n=42,97.7%)和观察法(n=41,95.3%)是最常用评估方法。研究提示常规实践中已收集部分结局指标,但仍缺乏可靠/经验证的手部烧伤结局测量工具。

要点

  • 患者视角下手部灵活性是手部烧伤后最重要的结局指标。
  • 伤后3个月(72.1%)和6个月(62.8%)是最常见的测量时间点。
  • Jamar握力计、量角器和捏力计是受访者最常引用的评估工具。

核心结论

  • 临床专科 allied health 人员在常规实践中收集部分手部烧伤后结局指标。
  • 基于受访者感知的使用障碍和缺乏可靠/经验证工具,需进一步研究。

研究设计与样本

  • 横断面调查研究,在某一时间点对样本 population 收集数据。
  • 共43名临床专科 allied health 专业人员回复问卷。

主要发现

  • 受访者指出患者认为手部灵活性是最重要的结局。
  • 伤后3个月是最常见测量时间点(n=31,72.1%),其次为6个月(n=27,62.8%)。
  • 患者报告手功能(n=42,97.7%)和观察法(n=41,95.3%)是最常报告的评估方法。
  • Jamar握力计(n=40,93%)、量角器(n=39,90.7%)和捏力计(n=36,83.7%)是最常被引用的评估工具。

关键数值与推荐

  • 《烧伤创伤康复: allied health 实践指南》倡导在不同时间点收集烧伤后结局指标,并推荐多种测量工具。

临床怎么用

  • 手部烧伤后可在伤后3个月和6个月重点评估手部灵活性、手功能等结局。
  • 临床可选用Jamar握力计、量角器和捏力计等工具进行手部烧伤后评估。

局限性

  • 受访者感知存在使用结局指标的障碍,且缺乏可靠/经验证的手部烧伤结局测量工具。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Outcome measures are used in healthcare to evaluate clinical practice, measure efficiencies and to determine the quality of health care provided. The Burns Trauma Rehabilitation: Allied Health Practice Guidelines advocates for the collection of outcome measures post burn injuries across different time points. These guidelines recommend multiple tools which can be utilized when measuring outcomes post burn injuries. The aim of this study was to gather information from specialist clinicians regarding their clinical practice and the outcome measurement tools used post hand burn injuries. This cross-sectional study used a survey design to collect data at one given point in time across a sample population. A total of 43 clinical specialists allied health professionals responded to the survey. Respondents indicated that their patients considered hand dexterity was the most important outcome. Three months post burn injury was the most common timepoint for measurement (n = 31, 72.1%) followed by six months (n = 27, 62.8%). Patient report of hand function (n = 42, 97.7%) and observation (n = 41, 95.3%) were the most frequently reported assessment methods. The Jamar Dynamometer (n = 40, 93%), goniometer (n = 39, 90.7%) and pinch gauge (n = 36, 83.7) were the most frequency cited assessment tools. The findings of this study suggest that clinical specialist allied health collect some outcome measures in their routine practice. Based on the respondent's perceptions of barriers when using outcome measures and lack of reliable/validated tools to measure hand burn outcomes, there is a need for further studies in this area.

来源:J Burn Care Res,查看原文。版权归原作者所有。

引用

  1. Mc Kittrick A, Gustafsson L. A Cross-sectional Survey of Health Professionals Across Australia and New Zealand to Determine What Outcome Measures Are Important From a Clinical Perspective Post Hand Burn Injury. J Burn Care Res. 2022. PMID: 34226927. doi:10.1093/jbcr/irab086

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。