低剂量CT在整形与重建外科中的拓展应用:基于多外科专科验证实践的系统综述
该系统综述基于PRISMA指南检索多外科专科中低剂量CT(LDCT)的验证应用,共纳入27篇文献。结果显示LDCT可使辐射剂量降低25%至97%,且图像质量与诊断能力不劣于标准剂量CT。作者据此推演出整形外科可拓展的应用场景,包括软组织感染评估、面部与手部骨折围手术期管理、皮瓣设计、3D建模及手术规划。
要点
- LDCT在多个外科专科中辐射剂量降低25%至97%,图像质量与诊断能力不劣于标准CT。
- 整形外科可拓展的LDCT应用包括软组织感染评估、面部与手部骨折围手术期管理。
- 皮瓣设计、3D建模与手术规划也是LDCT潜在的整形外科应用方向。
核心结论
- 低剂量CT是标准剂量CT的有效成像替代方案,整形外科应考虑扩大其使用以减少辐射医源性影响并促进患者安全而不损害结局。
研究设计与样本
- 按PRISMA指南开展的系统综述,检索词为「low dose CT」或「low dose computed tomography」与各外科专科名称组合,共识别3505篇文章,最终纳入27篇。
主要发现
- 根据应用不同,LDCT使辐射剂量降低25%至97%,所有研究报告图像质量与诊断能力不劣于标准剂量CT。
- 已识别的潜在应用包括软组织感染评估、面部与手部骨折的术前术后管理、皮瓣设计、3D建模及手术规划。
关键数值与推荐
- LDCT使辐射剂量降低25%至97%,所有纳入研究均报告图像质量与诊断能力不劣于标准剂量CT。
临床怎么用
- 整形外科医生可参考其他外科专科的验证实践,在软组织感染评估、面部与手部骨折围手术期管理、皮瓣设计、3D建模及手术规划中考虑使用LDCT。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: As computed tomography (CT) usage increases, so have concerns over radiation-induced malignancy. To mitigate these risks, low-dose CT (LDCT) has emerged as a versatile alternative by other specialties, although its use in plastic surgery remains sparse. This study aimed to investigate validated uses of LDCT across surgical specialties and extrapolate these insights to expand its application for plastic surgeons. METHODS: A systematic review of the literature was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines using search terms "low dose CT" OR "low dose computed tomography" AND "surgery," where the name of each surgical specialty was substituted for word "surgery" and each specialty term was searched separately in combination with the 2 CT terms. Data on radiation dose, outcomes, and level of evidence were collected. Validated surgical applications were correlated with similar procedures and diagnostic tests performed routinely by plastic surgeons to extrapolate potential applications for plastic surgeons. RESULTS: A total of 3505 articles were identified across surgical specialties, with 27 ultimately included. Depending on the application, use of LDCT led to a 25% to 97% reduction in radiation dose and all studies reported noninferior image quality and diagnostic capability compared with standard-dose CT. Potential identified uses included the following: evaluation of soft tissue infections, preoperative and postoperative management of facial and hand fractures, flap design, 3D modeling, and surgical planning. DISCUSSION: Low-dose CT is a valid imaging alternative to standard-dose CT. Expanded utilization in plastic surgery should be considered to minimize the iatrogenic effects of radiation and to promote patient safety without compromising outcomes.
引用
- Lala B, Shah J, Salvador TM, et al. Expanding the Utilization of Low-Dose Computed Tomography in Plastic and Reconstructive Surgery Based on Validated Practices Among Surgical Specialties. Ann Plast Surg. 2021. PMID: 33833174. doi:10.1097/SAP.0000000000002815
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。