负压伤口治疗在皮肤移植中的系统评价与Meta分析
结果显示NPWT提高移植皮片成活百分比、缩短从移植到出院天数、降低再手术相对风险,且未增加不良事件相对风险;亚组分析显示80 mmHg负压改善皮片成活百分比,而125 mmHg未见改善。
要点
- NPWT较非NPWT提高皮肤移植皮片成活百分比。
- NPWT缩短移植至出院天数并降低再手术相对风险。
- 80 mmHg负压可推荐,125 mmHg未见成活改善。
核心结论
- NPWT在皮肤移植整合方面比非NPWT更有效,可推荐80 mmHg负压。
- 不良事件与负压数据有限,需进一步理解并发症和理想负压。
研究设计与样本
- 系统评价与Meta分析,检索PubMed、Embase、Cochrane Library和CNKI至2020年2月。
主要发现
- NPWT提高移植皮片成活百分比。
- NPWT缩短从移植到出院天数。
- NPWT降低再手术相对风险。
- NPWT未增加不良事件相对风险。
- 亚组分析:80 mmHg负压改善皮片成活百分比,125 mmHg未见改善。
关键数值与推荐
- 80 mmHg负压可推荐用于改善皮片成活百分比。
- 125 mmHg负压未显示改善皮片成活百分比。
临床怎么用
- 皮肤移植患者可考虑使用NPWT以提高皮片成活。
- 负压参数可优先考虑80 mmHg。
- 需关注NPWT相关并发症及不良事件数据有限的问题。
局限性
- 不良事件数据有限。
- 负压相关数据有限。
- 需进一步研究NPWT并发症和皮肤移植整合的理想负压。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Although skin grafts are widely used in reconstruction of large skin defect and complex wounds, many factors lead to suboptimal graft take. Negative-pressure wound therapy (NPWT) reportedly increases the graft take rates when added to skin grafting, but a summary analysis of the data of randomized controlled trials has yet to be performed. We conducted this systematic review and meta-analysis of randomized controlled trials to compare the effectiveness and safety of NPWT and non-NPWT for patients with skin grafts. METHODS: We searched PubMed, Embase, Cochrane Library, and CNKI for relevant trials based on predetermined eligibility criteria from database establishment to February 2020. Two reviewers screened citations and extracted data independently. The quality of the included studies was evaluated according to the Cochrane Handbook, whereas statistical heterogeneity was assessed using chi-square tests and I2 statistics. Review Manager 5.3 was used for statistical analysis. RESULTS: Ten randomized controlled trials with 488 patients who underwent NPWT or non-NPWT were included. Compared with non-NPWT, NPWT yielded an improved the percentage of graft take, a reduction in days from grafting to discharge, with lower relative risk of re-operation, and no increased relative risk of adverse event. Further, the subgroup analysis showed an improved the percentage of graft take in negative pressure of 80 mmHg, and no improved the percentage of graft take in negative pressure of 125 mmHg. CONCLUSION: NPWT is more effective than non-NPWT for the integration of skin grafts, and the negative pressure of 80 mmHg can be recommended. Data on adverse events and negative pressure are, however, limited. A better understanding of complications after NPWT and the ideal negative pressure for the integration of skin grafts is imperative.
引用
- Jiang ZY, Yu XT, Liao XC, et al. Negative-pressure wound therapy in skin grafts: A systematic review and meta-analysis of randomized controlled trials. Burns. 2021. PMID: 33814213. doi:10.1016/j.burns.2021.02.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。