烧伤病房多重耐药菌暴发感染控制措施的系统综述
17个单位(81%)暴发被成功控制,8个单位关闭病房,其中6个(75%)暴发得到控制。适当的感染控制措施起重要作用,临时关闭病房在其它措施无效时应考虑。
要点
- 81%的烧伤病房MDRO暴发可通过感染控制措施成功控制。
- 关闭病房的8个单位中75%暴发得到控制,关闭原因含去污、调查和暴发未控。
- 筛查患者和环境培养、隔离、手卫生和加强清洁是常用干预措施。
核心结论
- 适当的感染控制措施在管理烧伤病房MDRO暴发中起重要作用。
- 临时关闭烧伤病房可能是控制院内传播的必要手段,当其他措施无效时应考虑。
研究设计与样本
- 系统综述,检索PubMed、EMBASE和Cochrane Central Register of Controlled Trials数据库,聚焦烧伤病房MDRO暴发的感染控制措施。
主要发现
- 17个单位(81%)暴发经干预成功控制,1个单位(4.7%)部分控制,3个单位(14.3%)未控制。
- 8个单位关闭烧伤病房,其中6个(75%)暴发得到控制。
- 关闭原因包括去污(4个单位,50%)、暴发调查(1个单位,12.5%)和暴发未控(3个单位,37.5%)。
- 4个单位关闭后感染发生率显著下降,但1个单位重新开放后感染率再次上升。
- 3个单位通过更换水疗设施、识别员工传播和病房结构改造等其他措施阻止了传播。
关键数值与推荐
- 筛查患者(19个单位)、筛查医护人员(17个单位)、环境培养(16个单位)、持续员工教育(13个单位)、队列或隔离(17个单位)、预emptive屏障预防(10个单位)、改善手卫生(15个单位)、加强清洁和环境消毒(17个单位)。
临床怎么用
- 烧伤病房应实施综合感染控制措施,包括患者和医护人员筛查、环境培养、隔离、手卫生和加强清洁消毒。
- 当其他措施无效时,可考虑临时关闭烧伤病房以控制MDRO传播。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Multidrug-resistant organisms (MDROs) pose a significant threat to severe burn victims and represents a clear epidemic hazard in burn units. Several infection control measures have been implemented to control and manage the outbreaks of MDRO. The efficiency of those measures, however, remains controversial and an area of debate. A systematic review was conducted to evaluate the efficacy of infection control measures and the necessity of closing burn units in dealing with MDRO outbreaks. METHODS: Peer-reviewed articles were identified using PubMed, EMBASE, and Cochrane Central Register of Controlled Trials databases, focusing on infection control measures to manage MDRO outbreaks in burn units. RESULTS: Twenty-one studies that reported MDRO outbreaks in burn units met the inclusion criteria. The outbreaks were successfully controlled with interventions in 17 units (81%), partially controlled in 1 unit (4.7%), and uncontrolled in 3 units (14.3%). Infection control measures were implemented by screening patient (19 units), screening health care worker (17 units), obtaining environmental cultures (16 units), providing ongoing staff education (13 units), cohort or isolation (17 units), preemptive barrier precautions (10 units), improving hand hygiene (15 units), and enhanced cleaning and environmental disinfection (17 units). Closure of burn units occurred in 8 units, with outbreaks controlled in 6 of the units (75%). The reasons for unit closure include decontamination (4 units; 50%), outbreak investigation (1 unit; 12.5%), and uncontrolled outbreaks (3 units; 37.5%). The incidence of infection was significantly decreased in 4 units after the closure but rose again after reopening in 1 of the units. In 3 units, the spread was halted by other control measures, including change of hydrotherapy facilities, identification of staff transmission, and unit structure remodeling. CONCLUSIONS: Proper infection control measures play an important role in managing MDRO outbreaks in burn units. Temporary closure of burn units may be necessary to control the spread of nosocomial, and this option should be considered when other measures are ineffective.
引用
- Wang C, Zhang F, Breland A, et al. Efficacy of Infection Control Measures in Managing Outbreaks of Multidrug-Resistant Organisms in Burn Units. Ann Plast Surg. 2021. PMID: 33833187. doi:10.1097/SAP.0000000000002825
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。