文献速递烧伤

成人烧伤后功能评估工具的系统综述

Instruments to assess function or functionality in adults after a burn injury: A systematic review.
PubMed 文献 · Burns · 2021-04-14

多数工具非烧伤专用且测量学特性研究不足,但几乎所有工具具有临床实用性。

要点

  • 仅3种烧伤专用工具,4种通用工具在烧伤人群中验证。
  • 多数工具测量学特性研究不足,但18种具临床实用性。

核心结论

  • 大多数用于评估成人烧伤后功能的工具并非专为该人群开发,且测量学特性研究不足。
  • 几乎所有工具均具有临床实用性。

研究设计与样本

  • 系统综述,检索6个电子数据库并筛查相关研究参考文献列表。
  • 排除儿童人群研究和会议摘要。
  • 综述在PROSPERO注册(CRD42016048065),按PRISMA声明报告。

主要发现

  • 发现3种烧伤专用工具。
  • 4种通用工具已在烧伤人群中验证。
  • 9项研究评估了工具的测量学特性,至少一种特性被评为「fair」质量。
  • 18种工具表现出临床实用性。

临床怎么用

  • 临床选用功能评估工具时需注意多数工具非烧伤专用且测量学特性证据有限。
  • 可优先考虑具有临床实用性的工具,但需结合测量学特性证据谨慎解读结果。

局限性

  • 多数工具的测量学特性研究不足,证据质量有限。
  • 仅纳入成人研究,排除儿童人群和会议摘要。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Assessment of functionality or function, through valid and reliable instruments, is essential during rehabilitation of adults after a burn injury. Currently, there is no consensus in the literature regarding the most appropriate tool that should be used to assess function or functionality; there is also no synthesis of the current studies published in this area. OBJECTIVES: To investigate and report the instruments used to assess function or functionality in adults after a burn injury; to identify the characteristics and evidence on their measurement properties; and to evaluate their clinical utility. METHODS: We systematically searched the literature via six electronic databases and via screening reference lists of relevant studies. The review was registered in PROSPERO (CRD42016048065) and reported according to the PRISMA statement. Studies in which function or functionality of upper and/or lower limbs of adults after a burn injury was assessed were included. Exclusion criteria comprised studies in pediatric populations and conference abstracts. RESULTS: Thirty-four studies were included. Twelve questionnaires and seven objective tests for function or functionality were identified. Three specific tools were found; four generic instruments have been validated in burns. Nine studies evaluated the instruments' measurement properties, presenting at least one property classified as 'fair' quality. Finally, 18 instruments demonstrated clinical utility. CONCLUSION: This systematic review demonstrated that most instruments used to assess function or functionality in adults with a burn injury have not been specifically developed for this population and had their measurement properties poorly studied. Conversely, almost all instruments had clinical utility.

来源:Burns,查看原文。版权归原作者所有。

引用

  1. Itakussu EY, Morita AA, Kakitsuka EE, et al. Instruments to assess function or functionality in adults after a burn injury: A systematic review. Burns. 2021. PMID: 33896659. doi:10.1016/j.burns.2021.04.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。