伊朗电烧伤7年回顾性研究:726例流行病学与特征分析
该横断面描述性研究分析了2014至2019年住院的726例电烧伤患者,平均年龄31.17岁,平均TBSA为16.61±12.56。患者以男性(95.7%)和无固定职业者(63%)为主,低压伤占89%,63%发生于工作场所,12.2%接受截肢。高压与低压伤在TBSA、住院时间、手术方式及死亡率等方面差异有统计学意义(P=.001)。
要点
- 低压电烧伤占89%,高于高压伤,与既往研究不同。
- 63%事故发生于工作场所,无固定职业者占63%。
- 高压与低压伤在TBSA、住院时间、截肢及死亡率差异显著(P=.001)。
核心结论
- 电烧伤仍是创伤患者致病和致死的重要原因。
- 本组低压电烧伤比高压更常见,与既往研究相反。
- 改进电器制造、重视安全措施及教育培训可减少事故和死亡率。
研究设计与样本
- 横断面描述性研究,纳入2014至2019年住院的电烧伤患者共726例,平均年龄31.17岁。
主要发现
- 平均TBSA为16.61±12.56。
- 男性696例(95.7%),无固定职业者458例(63%)。
- 最常见烧伤部位为手(28.6%)和上肢(27.8%)。
- 89例(12.2%)接受截肢,以手指(64例)最常见。
- 低压伤649例(89%),工作场所事故459例(63%)。
关键数值与推荐
- 高压与低压伤在TBSA、平均住院时间、焦痂切除、筋膜切开、截肢、清创、骨折及死亡率方面差异有统计学意义(P=.001)。
临床怎么用
- 应重视低压电烧伤的防治,关注手部及上肢等常见部位。
- 加强工作场所安全措施与教育培训,可能降低事故发生率和死亡率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Electrical burn injuries can cause devastating and debilitating morbidities and impairments for patients. This cross-sectional descriptive study was performed on electrical burn patients hospitalized from 2014 to 2019 to evaluate electrical burn injuries' epidemiology and characteristics. A total number of 726 patients with the mean age of 31.17 years were evaluated for electrical burn injuries. Mean total burn surface area (TBSA) was 16.61 ± 12.56. Most victims were male (696 cases, 95.7%) and most patients did not have a constant job (n = 458, 63%). Most affected burn sites were hands (28.6%) and upper limbs (27.8%). A total number of 89 (12.2%) patients suffered amputations with the hand fingers (64 cases) as the most common site. Low-voltage injuries were more common (n = 649, 89%). Most incidents happened at the workplace (n = 459, 63%). Comparison of patients with high-voltage and low-voltage injuries showed significant correlations and statistical difference between these two groups regarding TBSA, mean hospital stays, escharectomy, fasciotomy, amputations, debridement, fracture, and mortality rate (P = .001). Our observation revealed that electrical burn injuries are still significant causes of morbidity and mortality among trauma patients. In contrast to previous studies, low-voltage injuries were more common than high-voltage ones. We propose improvements in the manufacturing of electrical appliances; paying attention to safety measures will reduce the number of incidents. Moreover, training and education play important roles in reducing the number of incidents and mortality rates.
引用
- Vaghardoost R, Saraee A, Ghavami Y, et al. Evaluation of Electrical Burn Injuries in Iran: A 7-Year Retrospective Study. J Burn Care Res. 2022. PMID: 33886962. doi:10.1093/jbcr/irab070
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。