文献速递烧伤

动脉血气参数与胸片预测烧伤疑似吸入性损伤患者适宜插管的价值:回顾性队列研究

The utility of arterial blood gas parameters and chest radiography in predicting appropriate intubations in burn patients with suspected inhalation injury-A retrospective cohort study.
PubMed 文献 · Burns · 2021-02-27

本研究评估动脉血气(ABG)参数和胸片对烧伤疑似吸入性损伤患者插管需求的预测价值。pH和P/F比值预测适宜插管良好(AUROC分别为0.88和0.81),加入ABA标准可提高敏感性(0.97 vs 0.86,p=0.013)而不改变特异性。

要点

  • pH<7.30预测适宜插管敏感性和特异性均为80%。
  • P/F比值<40预测适宜插管敏感性和特异性均为70%。
  • pH和P/F比值加入ABA标准可提高敏感性至0.97。

核心结论

  • 在烧伤疑似吸入性损伤患者中,pH和P/F比值是适宜插管的良好预测指标。
  • 将pH和P/F比值纳入ABA标准可提高临床效用。

研究设计与样本

  • 单中心回顾性队列研究,纳入2016年4月4日至2019年7月5日烧伤ICU收治的疑似吸入性损伤患者。
  • 计算受试者工作特征曲线下面积(AUROC)。

主要发现

  • 84%(n=75)患者接受插管,其中81%(n=61)为适宜插管。
  • pH的AUROC为0.88,pH<7.30检测适宜插管的敏感性和特异性均为80%。
  • P/F比值的AUROC为0.81,P/F比值<40检测适宜插管的敏感性和特异性均为70%。
  • 胸片阴影的AUROC为0.69,效用较差。

关键数值与推荐

  • 适宜插管定义为插管持续时间超过48小时。
  • pH<7.30:敏感性80%,特异性80%。
  • P/F比值<40:敏感性70%,特异性70%。
  • 胸片阴影:AUROC=0.69。
  • ABA标准+pH+P/F比值敏感性0.97 vs ABA标准0.86,p=0.013,特异性无改变。

临床怎么用

  • 对疑似吸入性损伤的烧伤患者,可考虑使用入院pH和P/F比值辅助预测是否需要适宜插管。
  • 将pH和P/F比值纳入ABA标准可提高识别适宜插管的敏感性,有助于临床决策。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study evaluates the utility of arterial blood gas (ABG) parameters and chest radiography in predicting intubation need in patients with burn injuries with suspected inhalation injury. METHODS: Patients with suspected inhalation injury admitted to a single centre, Burn Intensive Care Unit, between April 4th 2016 and July 5th 2019, were included. Admission ABG parameters and chest radiograph opacification were compared with whether the patient received an appropriate intubation: defined as intubation for a duration of over 48 h. Area under the receiver operator characteristic curve was calculated (AUROC). RESULTS: Eighty-nine patients were included. The majority (84%; n = 75) were intubated, of which 81% (n = 61) received appropriate intubations. pH had an AUROC of 0.88 and a pH of <7.30 had an 80% sensitivity and specificity for detecting appropriate intubation. P/F ratio had an AUROC of 0.81 and a P/F ratio of <40 had a 70% sensitivity and specificity for appropriate intubation. Chest radiograph opacification had poor utility in this regard (AUROC = 0.69). Adding pH and P/F ratio to the ABA criteria improved their sensitivity in detecting appropriate intubations (sensitivity: ABA + pH + P/F = 0.97 vs ABA = 0.86; p = 0.013), without altering their specificity. CONCLUSIONS: In patients suspected inhalation injury, pH and P/F ratio were good predictors for appropriate intubations. Incorporating the parameters into the ABA criteria improved their clinical utility.

来源:Burns,查看原文。版权归原作者所有。

引用

  1. Chotalia M, Pirrone C, Ali M, et al. The utility of arterial blood gas parameters and chest radiography in predicting appropriate intubations in burn patients with suspected inhalation injury-A retrospective cohort study. Burns. 2021. PMID: 33707087. doi:10.1016/j.burns.2021.02.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。