低功率纯切单极电外科与缝扎固定预防背阔肌皮瓣供区血清肿
本研究纳入112例乳腺癌保乳术后即刻背阔肌皮瓣乳房重建患者,比较三种供区处理方式对血清肿的影响。低功率纯切模式较电凝模式显著降低术后1周引流量和拔管时间,联合缝扎固定进一步减少血清肿形成。
要点
- 低功率纯切模式可减少背阔肌皮瓣供区引流量和拔管时间
- 联合缝扎固定进一步降低血清肿发生率至6.1%
- 该组合无需特殊设备,可能降低患者负担和医疗成本
核心结论
- 低功率纯切模式用于背阔肌皮瓣获取联合缝扎固定,能有效缩短拔管时间并抑制血清肿形成。
研究设计与样本
- 回顾性研究纳入2015年4月至2019年1月间112例保乳术后即刻背阔肌皮瓣乳房重建患者,分三组:A组21例用电凝模式,B组25例用低功率纯切模式,C组66例用低功率纯切模式联合缝扎固定。
主要发现
- 术后1周平均背侧引流量和平均拔管天数:A组752.3 mL和16.9天,B组552.2 mL和10.6天,B组较A组显著减少(P<0.001)。
- C组引流量和拔管天数分别为459.7 mL和7.4天,均低于B组(P=0.03和P<0.001)。
- 供区血清肿发生率:A组16/21(76.2%),B组11/25(44%),C组4/66(6.1%);A与B比较P<0.001,B与C比较P<0.001。
临床怎么用
- 在背阔肌皮瓣获取时采用低功率纯切模式,并联合缝扎固定关闭供区,可减少血清肿和引流时间。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Latissimus dorsi myocutaneous (LD) flaps are widely used in breast reconstruction surgery. However, seromas often form postoperatively at the donor site as a complication. This study aimed to determine the impact of different electrocautery modes during flap elevation, with or without subsequent quilting sutures, on postoperative seroma formation. METHODS: Subjects were 112 patients who underwent immediate breast reconstruction with LD flaps after breast-conserving surgery between April 2015 and January 2019. Group A consisted of 21 patients who underwent LD flap elevation using the fulgurate mode, and group B consisted of 25 patients who underwent flap elevation using the lower power, pure cut mode. Group C consisted of 66 patients who underwent flap elevation with the lower power, pure cut mode combined with quilting sutures for wound closure. RESULTS: Mean 1-week postoperative back drain volume and the mean number of days to drain removal in group B were significantly reduced relative to those in group A (group A, 752.3 mL and 16.9 days, respectively; group B, 552.2 mL and 10.6 days, respectively; P < 0.001 for both). Group C, which included quilting sutures, had even lower values than group B (459.7 mL and 7.4 days, respectively; group B vs group C: P = 0.03 and P < 0.001, respectively). Significant differences were observed between groups for postoperative seroma formation at the flap donor site (group A, 16 [76.2%] of 21 patients; group B, 11 [44%] 25 patients; group C, 4 [6.1%] of 66 patients; A vs B: P < 0.001, B vs C: P < 0.001). CONCLUSIONS: The use of low power, pure cut mode for LD flap harvest, combined with quilting sutures, effectively shortened the time to drain removal and suppressed seroma formation. Given that specialized devices and materials are not required, this combination may reduce both patient burden and medical costs.
引用
- Tashima H, Tomita K, Kurita T, et al. Efficacy of Low Power, Pure Cut Mode of Monopolar Electrosurgery and Quilting Sutures for Preventing Seroma Formation After Latissimus Dorsi Myocutaneous Flap Harvest. Ann Plast Surg. 2021. PMID: 33555680. doi:10.1097/SAP.0000000000002545
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。