合成与生物补片联合用于胸肌前即刻假体乳房再造以降低成本
本文描述一种胸肌前乳房再造技术,将前侧假体覆盖分为下外侧脱细胞真皮基质(ADM)与上方可吸收合成网片,并回顾单中心连续病例。
要点
- 胸肌前即刻假体再造中,下方用ADM覆盖并加强乳房下皱襞,上方用可吸收网片支撑假体。
- 该技术可降低支撑材料成本,单侧至多节省3415美元,双侧至多6830美元。
核心结论
- 胸肌前乳房再造采用下方ADM与上方Vicryl网片联合覆盖是安全技术,可降低支撑材料成本并精确控制假体腔隙与位置。
主要发现
- 平均乳房切除重量为775.8 g,所有病例使用光滑圆形cohesive假体,平均假体大小为514.5 ml。
- 总体并发症率低,包括1例轻微感染(4.8%)、1例轻微乳房切除皮瓣坏死(4.8%)和1例部分乳头坏死(4.8%)。
- 计算Vicryl与ADM前侧覆盖的成本节省:单侧至多3415美元,双侧至多6830美元。
关键数值与推荐
- 前侧覆盖分为下外侧ADM与上方可吸收合成网片,网片修剪后以适当张力与ADM缝合以支撑假体并减轻皮瓣压力。
- 证据等级为治疗性IV级。
临床怎么用
- 在胸肌前即刻假体乳房再造中,可采用下方ADM加强乳房下皱襞、上方Vicryl网片支撑假体的混合覆盖策略以降低材料成本。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
SUMMARY: Prepectoral breast reconstruction has minimized morbidity and dynamic deformities associated with submuscular implant-based breast reconstruction. However, reliance on implant coverage with acellular dermal matrix in immediate implant reconstruction remains limited by high material costs. The authors describe a technique in which anterior implant coverage in prepectoral reconstruction is split into acellular dermal matrix inferolaterally and synthetic, absorbable mesh superiorly. Use of acellular dermal matrix inferiorly provides coverage and reinforces the inframammary fold, whereas the absorbable mesh is trimmed and sutured to the acellular dermal matrix at the appropriate tension to support the implant and relieve pressure on mastectomy flaps. A retrospective review was performed on all consecutive prepectoral one-stage breast reconstructions using this technique at a single institution. Patient demographics, mastectomy and reconstruction characteristics, reconstructive outcomes, and cost of support materials were queried and analyzed. Eleven patients (21 breasts) underwent prepectoral immediate implant reconstruction with Vicryl and acellular dermal matrix anterior coverage. Average mastectomy weight was 775.8 g. Smooth, round cohesive implants were used in all cases and average implant size was 514.5 ml. Overall complication rates were low and included one minor infection (4.8 percent) and one case of minor mastectomy flap and partial nipple necrosis each (4.8 percent). Calculated cost savings of Vicryl and acellular dermal matrix anterior coverage was up to $3415 in unilateral and $6830 in bilateral cases. Prepectoral breast reconstruction using acellular dermal matrix inferiorly and Vicryl mesh superiorly is a safe technique that decreases material costs associated with support materials and allows the surgeon to precisely control the implant pocket and position. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.
引用
- Karp NS, Salibian AA. Splitting the Difference: Using Synthetic and Biologic Mesh to Decrease Cost in Prepectoral Immediate Implant Breast Reconstruction. Plast Reconstr Surg. 2021. PMID: 33620924. doi:10.1097/PRS.0000000000007638
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。