止血带-再灌注增强热成像检测穿支:小腿远端重建的改良方法与初步报告
本研究介绍一种通过止血带-再灌注增强热成像(TRATIM)检测穿支的方法,并与CTA对比,同时报告9例小腿远端重建的初步应用。结果显示TRATIM灵敏度90.3%、阳性预测值93.3%,与CTA一致性极好(kappa=0.839,P<0.001),9例螺旋桨穿支皮瓣均成功设计并切取,除1例1.0 cm×2.0 cm皮瓣末端坏死外全部存活。
要点
- TRATIM在止血带释放后20-140秒观察窗内检测穿支,灵敏度90.3%、阳性预测值93.3%
- TRATIM与CTA一致性极好(kappa=0.839,P<0.001),可辅助设计小腿远端螺旋桨穿支皮瓣
- 9例皮瓣除1例1.0 cm×2.0 cm末端坏死外全部存活,初步显示方法可靠
核心结论
- TRATIM是检测小腿穿支快速、简便、廉价且可靠的方法,可高效辅助定制螺旋桨穿支皮瓣用于小腿远端重建。
研究设计与样本
- 方法学研究与初步临床报告:大腿近端施加450 mmHg止血带3分钟,释放后以热成像观察复温速率和热点模式,并与CTA对比。
- 临床对9例患者行局部转移的胫后动脉或腓动脉螺旋桨穿支皮瓣修复小腿远端。
主要发现
- 止血带释放后存在20-140秒的「穿支观察窗」。
- TRATIM灵敏度90.3%,阳性预测值93.3%。
- TRATIM与CTA一致性极好,kappa指数0.839(P<0.001)。
- 基于TRATIM成功设计并切取9例螺旋桨穿支皮瓣,除1例1.0 cm×2.0 cm皮瓣末端坏死外全部完全存活。
临床怎么用
- 可在小腿远端重建术前采用止血带-再灌注增强热成像快速定位穿支并评估质量。
- 依据TRATIM结果可定制设计螺旋桨穿支皮瓣,提高皮瓣切取效率。
局限性
- 原文为初步报告,样本量有限(9例临床患者)。
- 原文未报告随机对照或长期随访结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Dynamic infrared thermography provides a new imaging method of perforator detection. This study introduces an augmented technique to improve its accuracy by tourniquet-reperfusion and reports its preliminary use in the distal lower leg reconstruction. METHODS: A tourniquet (450 mm Hg) was applied for 3 minutes on proximal thighs. After the tourniquet release, the rewarming rate and pattern of hotspots were observed by thermography to delineate the location and quality of perforators. The results were compared with those detected by computed tomographic angiography. Clinically, the local transferred posterior tibial artery or peroneal artery propeller perforator flap was performed in 9 patients for the distal lower leg reconstruction. RESULTS: There was a 20- to 140-second "perforator observing window" after the tourniquet release. Tourniquet-reperfusion augmented thermal imaging method (TRATIM) had a sensitivity of 90.3% and a positive predictive value of 93.3%. The TRATIM and computed tomographic angiography had an excellent concordance with a kappa index value of 0.839 (P < 0.001). Based on the TRATIM, 9 propeller perforator flaps were successfully designed and raised for the distal lower leg resurfacing. All flaps survived entirely, except one with size of 1.0 cm × 2.0 cm that had terminal necrosis. CONCLUSIONS: The TRATIM is a quick, easy, cheap, and reliable approach for perforator detection in the lower leg. With the aid of TRATIM, a customized propeller perforator flap could be raised efficiently for the distal lower leg reconstruction.
引用
- Pan JD, Xu H, Xiao DC, et al. Perforator Detection by Thermographic Imaging Augmented With Tourniquet-Reperfusion: A Modified Approach and Preliminary Report in Distal Lower Leg Reconstruction. Ann Plast Surg. 2021. PMID: 33587459. doi:10.1097/SAP.0000000000002741
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。