文献速递乳房整形与再造显微修复重建

自体乳房再造中使用胸廓内血管时气胸风险研究

Risk of Pneumothorax With Internal Mammary Vessel Utilization in Autologous Breast Reconstruction.
PubMed 文献 · Ann Plast Surg · 2021-01-01

单机构4年回顾性研究评估DIEP皮瓣乳房再造中胸廓内血管吻合后气胸发生率。180例患者中4例发生气胸,总体发生率为每100次受区血管解剖1.4例、每100例患者2.2例。作者认为气胸并非常见并发症,术中可疑胸膜损伤可用盐水气泡试验,无症状者无需常规术后胸片。

要点

  • DIEP乳房再造中胸廓内血管吻合后气胸发生率低(每100例患者2.2例)。
  • 术中怀疑胸膜损伤时可用盐水气泡试验探查。
  • 无气胸症状者不推荐常规术后胸部X线检查。

核心结论

  • 胸廓内动静脉仍是自体乳房再造最常用可靠的受区血管,气胸并非常见并发症。

研究设计与样本

  • 单机构回顾性研究,分析4年间180例DIEP皮瓣乳房再造并使用胸廓内血管吻合的病例。

主要发现

  • 共发生4例气胸,总体发生率为每100次受区血管解剖1.4例、每100例患者2.2例。
  • 3例气胸原因不明,1例为电刀直接损伤壁层胸膜所致。

关键数值与推荐

  • 术中若怀疑医源性胸膜损伤,建议使用盐水气泡试验探查。
  • 除非患者出现提示气胸的症状,否则不推荐常规术后胸部X线检查。

临床怎么用

  • 在DIEP乳房再造解剖胸廓内血管时,应警惕胸膜损伤可能,必要时行盐水气泡试验。
  • 术后不必常规拍摄胸片,仅对出现气胸症状的患者进行影像学评估。

局限性

  • 单机构回顾性设计,样本量有限,气胸事件数少。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Complications associated with autologous breast reconstruction are well reported in the literature. Regardless of the type of free flap harvested, the anastomosis is most commonly performed to the recipient internal mammary vessels. Although pneumothorax is a known possible complication of breast surgery, incidence of pneumothorax in breast reconstruction involving the use of the internal mammary vessels is rarely discussed. The aim of our study was to determine the incidence of pneumothorax in deep inferior epigastric perforator (DIEP) flap breast reconstruction. METHODS: A single-institution review was performed examining the incidence of pneumothorax in cases of DIEP flap breast reconstruction with anastomosis to the internal mammary vessels over a 4-year period. Intraoperative irrigation was used to visually assess for evidence of pneumothorax during recipient vessel dissection and anastomosis. Anteroposterior chest radiographs were obtained on the first postoperative day to assess for pneumothorax. Additional variables analyzed included type of retractor used during recipient vessel dissection and history of radiation. RESULTS: A total of 180 patients underwent autologous DIEP breast reconstruction at our institution. The overall incidence of pneumothorax was 1.4 per 100 recipient vessel dissections and 2.2 per 100 patients undergoing breast reconstruction. There was a total of 4 cases of pneumothorax. Three were attributed to unknown causes, and 1 was due to direct injury to the parietal pleura via electrocautery. CONCLUSION: The use of the internal mammary artery and vein as recipient vessels continues to be the most common and reliable recipient for autologous breast reconstruction. Based on our data, pneumothorax does not seem to be a common complication of this procedure. If concern for iatrogenic injury to the pleura arises intraoperatively, we suggest the use of a saline bubble test to investigate the possible injury. Routine postoperative radiographs are not indicated unless the patient develops symptoms suggestive of pneumothorax.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Kelling JA, Meade A, Adkins M, et al. Risk of Pneumothorax With Internal Mammary Vessel Utilization in Autologous Breast Reconstruction. Ann Plast Surg. 2021. PMID: 33470623. doi:10.1097/SAP.0000000000002643

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。