单侧DIEP皮瓣乳房再造术前穿支定位不同影像模态准确性的系统评价与Meta分析
该系统评价与Meta分析纳入21篇文献共1146例成年女性,评估术前穿支定位影像与术中确认的一致性。Meta分析显示影像认定的优势穿支94%(95%CI 88-99%)被术中选为优势穿支;彩色多普勒(Duplex)超声一致性最低(均值74% [95%CI 67-81%]),MRA最高(均值97% [95%CI 86-100%]),各检查间差异无统计学意义。
要点
- 影像认定的优势穿支94%(95%CI 88-99%)术中确认为优势穿支。
- 彩色多普勒超声一致性最低(均值74% [95%CI 67-81%]),MRA最高(均值97% [95%CI 86-100%])。
- 横断面成像(CT/MR)准确性相似且优于超声,但证据有限。
核心结论
- 基于有限证据,术前DIEP穿支定位的横断面成像(CT/MR)准确性相似且优于超声。
研究设计与样本
- 系统评价与Meta分析,检索MEDLINE和EMBASE自建库至2019年9月24日,纳入21篇文献共1146例成年女性。
- 索引试验为术前影像,参考标准为术中穿支确认。
主要发现
- 共描述6种方法:手持多普勒、彩色多普勒(Duplex)超声、CT血管造影、磁共振血管造影(MRA)、直接红外热成像(联合或不联合多普勒)。
- 影像认定的优势穿支94%(95%CI 88-99%)被术中选为优势穿支。
- 彩色多普勒(Duplex)超声一致性最低(均值74% [95%CI 67-81%]),MRA最高(均值97% [95%CI 86-100%])。
- 不同检查间性能差异无统计学意义。
临床怎么用
- 术前穿支定位可优先考虑横断面成像(CT/MR),其准确性相似且优于超声。
局限性
- 所有研究均存在偏倚,因操作者在实施参考标准前已知索引试验结果。
- 证据有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Perforator mapping may be performed prior to deep inferior epigastric perforator (DIEP) flap breast reconstruction to guide perforator selection. However, the accuracy of different imaging modalities remains unknown. This review aimed to evaluate the accuracy of different modalities for locating perforators for unipedicled DIEP flap breast reconstruction. METHODS: MEDLINE and EMBASE were searched from inception to 24th September 2019 for studies concerning adult women undergoing DIEP flap breast reconstruction with preoperative perforator mapping. The index test was pre-operative imaging and the reference standard was intraoperative identification. RESULTS: 21 articles with 1146 women were included. Six methods were described; handheld doppler, colour doppler (duplex) ultrasonography, computed tomography angiography, magnetic resonance angiography (MRA), direct infrared thermography with and without doppler. Meta-analysis revealed 94% (95% CI 88-99%) of DIEPs identified as the 'dominant perforator' on imaging were chosen as dominant perforators intraoperatively. Colour doppler (Duplex) ultrasonography had the lowest agreement (mean 74% [95% CI 67-81%]) whilst MRA had the highest agreement (mean 97% [95% CI 86-100%]). There was no statistically significant difference in the performance of different tests. All studies were subject to bias as the operators had knowledge of the index test prior to conducting the reference standard. CONCLUSIONS: Based upon limited evidence, cross sectional (CT/MR) imaging modalities for preoperative DIEP mapping appear to have similar accuracy and perform better than ultrasound.
引用
- Kiely J, Kumar M, Wade RG, et al. The accuracy of different modalities of perforator mapping for unilateral DIEP flap breast reconstruction: A systematic review and meta-analysis. J Plast Reconstr Aesthet Surg. 2020. PMID: 33342741. doi:10.1016/j.bjps.2020.12.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。