文献速递乳房整形与再造美容整形

乳房增大术中引流是否有效:前瞻性多中心随机对照研究

Drainage on augmentation mammoplasty: Does it work?
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2020-11-07

该前瞻性多中心随机对照试验纳入150例乳房增大术患者,随机分为闭式负压引流组与无引流对照组,比较术后并发症。结果显示两组在第7天和第3个月超声评估上无显著差异,引流组48小时总引流量平均119.7 ml,结论认为闭式负压引流成本高、耗时且近期无获益。

要点

  • 闭式负压引流在乳房增大术中未显示近期并发症获益。
  • 术后48小时总引流量平均119.7 ml,范围22–320 ml。
  • 两组第7天和第3个月超声评估无显著差异。

核心结论

  • 乳房增大术中闭式负压引流成本高、耗时,且近期术后未显示获益。

研究设计与样本

  • 前瞻性多中心随机对照临床试验,纳入150例乳房增大术候选患者,分为闭式负压引流组和无引流对照组。

主要发现

  • 术后第1个24小时引流量范围12–210 ml,均值74.90 ml(SD=43.29 ml)。
  • 术后第2个24小时引流量范围10–120 ml,均值44.76 ml(SD=24.80 ml)。
  • 48小时总引流量范围22–320 ml,均值119.7 ml(SD=62.20 ml)。
  • 两组第7天和第3个月乳腺超声评估无显著差异(p=0.05和0.25)。
  • 随访中33–44%患者报告乳头乳晕复合体及乳房下段感觉异常。

临床怎么用

  • 乳房增大术者可参考本试验结果,权衡闭式负压引流的成本与耗时,近期并发症预防方面未见明确获益。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Breast prostheses could be associated with complications, despite many studies on surgical materials and techniques. The role of surgical drainage in preventing complications on breast prostheses surgery is controversial. OBJECTIVES: This study aimed to evaluate the role and effectiveness of vacuum drainage in the augmentation mammoplasty. METHODS: A prospective multicentric randomized comparative clinical trial was conducted with 150 patients, who were the candidates for breast augmentation. The candidates were split into two groups to analyze the breast drain role. Group1: closed-suction drainage; measurements were taken every 24 h for 48 h. Group2: control (no drainage); all the patients were submitted to a clinical and postoperative ultrasonography evaluation (7th day and 3rd month). The late consultations (1st-, 2nd-, and 3rd-year postoperative time) were carried out to identify any complication, such as infection, seroma, hematoma, asymmetry, hypertrophic scarring, rippling, implant position, visible edges, and sensibility alteration. RESULTS: A total of 150 female patients were operated with 300 breast implants placed into subglandular pocket. In the first 24 h postoperative (D1), the drainage volume ranged from 12 ml to 210 ml (mean= 74.90 ml; SD= 43.29 ml). After 24 h, on the second day (D2), the collected volume ranged from 10 ml to 120 ml (mean= 44.76 ml; SD= 24.80 ml). The total drainage volume in the 48 h ranged from 22 ml to 320 ml (mean= 119.7 ml; SD= 62.20 ml). The breast ultrasonography series (BUSGS) analysis was done on the 7th day and 3rd month in both groups. There was no significant difference between G1 and G2 groups (p = 0.05 and 0.25, respectively). In the follow-up, some patients (33-44%) declared sensitivity disturbing on the nipple-areola complex (NAC) and lower breast segment. CONCLUSIONS: The closed-suction breast drainage in breast augmentation was associated with high cost and time-consuming and not demonstrated any benefit in a recent postoperative time.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Charles-de-Sá L, Gontijo-de-Amorim NF, Rossi JK, et al. Drainage on augmentation mammoplasty: Does it work? J Plast Reconstr Aesthet Surg. 2020. PMID: 33250388. doi:10.1016/j.bjps.2020.10.059

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。