眶周形态量化新方法:直接、二维与三维技术比较
结果显示三维与二维测量相关性最高(grand r=0.88),直接与三维及直接与二维的grand r分别为0.78和0.77;各方法间平均绝对差异约1 mm。结论支持该标准化标志点定位方案在眶周形态评估中的可行性。
要点
- 三维与二维测量的一致性最高(grand r=0.88),直接测量与两者一致性相近(r=0.77–0.78)。
- 直接与三维、直接与二维的平均绝对差异均约1 mm,二维与三维间约1 mm和6.6°。
- 该标准化24标志点、19线性+3角度方案可用于眶周形态的二维与三维评估。
核心结论
- 研究验证了该详细标准化标志点定位方案用于二维和三维技术评估眶周形态的可行性。
- 该方案有望成为未来涉及三种技术中任一种的研究之间的沟通桥梁。
研究设计与样本
- 每张三维照片按标准化方案定位24个标志点,测量19项线性与3项角度眶周变量。
- 对每名受试者进行二维与直接测量,并与三维测量及彼此比较。
主要发现
- 直接与二维、直接与三维、三维与二维测量的grand r分别为0.77、0.78、0.88。
- 直接与三维测量平均绝对差异为1 mm(范围0.2 mm至3.7 mm)。
- 直接与二维测量平均绝对差异为1 mm(范围0.04 mm至2.4 mm)。
- 二维与三维测量平均绝对差异为1 mm和6.6°(范围0.04 mm或0.5°至3 mm或12.8°)。
临床怎么用
- 眶周形态评估可采用该标准化24标志点定位方案配合二维或三维技术。
- 三维与二维测量一致性较高,直接测量与两者平均差异约1 mm,可互为参考。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The measurement of anatomical structures is critical in plastic and reconstructive surgery. However, few detailed and standardized measurements have been widely used in the periorbital region. This study aimed to evaluate the feasibility of a novel detailed and standardized protocol with 2D and 3D technologies, and explore the relationship between them and direct measurements. METHODS: Fifty healthy Caucasians (100 eyes) between 20 and 68 years old were recruited and captured for 3D photographs by VECTRA M3 3D Imaging System. Subsequently, 24 landmarks were located on each 3D photographs following a standardized protocol, and then 19 linear and 3 angular periorbital variables were measured. Furthermore, two-dimensional (2D) and direct measurements were conducted on each subject and compared with 3D measurements and one another. RESULTS: The grand r means across all measurements were 0.77, 0.78, and 0.88 for direct vs. 2D values, direct vs. 3D values, and 3D vs. 2D values, respectively. The mean absolute differences were 1 mm (ranging from 0.2 mm to 3.7 mm) between direct and 3D measurements, 1 mm (ranging from 0.04 mm to 2.4 mm) between direct and 2D measurements, and 1 mm and 6.6° (ranging from 0.04 mm or 0.5° to 3 mm or 12.8°) between 2D and 3D measurements. CONCLUSIONS: This study verified the feasibility of this detailed and standardized landmark localization protocol for assessing the periorbital morphology with 2D and 3D technologies. This protocol may work as a bridge communicating with all studies involving any of the three technologies in the future.
引用
- Guo Y, Liu J, Ruan Y, et al. A novel approach quantifying the periorbital morphology: A comparison of direct, 2-dimensional, and 3-dimensional technologies. J Plast Reconstr Aesthet Surg. 2020. PMID: 33358464. doi:10.1016/j.bjps.2020.12.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。