文献速递创面修复瘢痕与激光

新型可吸收吻合器在皮肤闭合中患者报告结局与成本效益不劣于皮内缝合:前瞻性单盲随机临床试验

A Novel Absorbable Stapler Provides Patient-Reported Outcomes and Cost-Effectiveness Noninferior to Subcuticular Skin Closure: A Prospective, Single-Blind, Randomized Clinical Trial.
PubMed 文献 · Plast Reconstr Surg · 2020-01-01

该研究为法国26家医院的前瞻性、患者盲法、随机、多中心非劣效性试验,纳入660例患者随机1:1接受传统缝线或半自动吻合器真皮缝合。主要终点3个月患者瘢痕评估量表评分吻合器组不劣于缝线组,缝合时间显著缩短,职业性血液暴露更少,并发症无显著差异,每例额外成本51.57欧元。

要点

  • 半自动吻合器真皮缝合在3个月和18个月患者瘢痕评估量表评分上不劣于传统缝线。
  • 吻合器组平均缝合时间显著低于缝线组,总体手术时间两组无显著差异。
  • 吻合器组职业性血液暴露1例,缝线组7例;并发症两组无显著差异。

核心结论

  • 使用半自动吻合器进行真皮缝合的伤口愈合结局不劣于传统缝线缝合,且职业性血液暴露更少。

研究设计与样本

  • 前瞻性、患者盲法、随机、多中心非劣效性研究,在法国26家医院开展,660例患者随机1:1分为吻合器组和缝线组,649例纳入全分析(吻合器组n=324,缝线组n=325)。

主要发现

  • 主要终点3个月患者瘢痕评估量表评分吻合器组不劣于缝线组,18个月后同样不劣。
  • 吻合器组平均手术时间180分钟,缝线组179分钟(p=无显著差异);吻合器组平均缝合时间显著更低(p<0.001)。
  • 职业性血液暴露缝线组7例,吻合器组1例;两组并发症无显著差异(p=0.41)。
  • 使用该器械的额外成本为每例51.57欧元(完整病例人群)。

临床怎么用

  • 在需真皮缝合的伤口闭合中,可考虑使用半自动吻合器以缩短缝合时间并减少职业性血液暴露,其患者报告瘢痕结局不劣于传统缝线。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Deep dermal suturing is critical for scar quality outcomes. The authors evaluated a new, fast medical device for dermal suturing, with the hypothesis of noninferiority with regard to clinical scar and cost-effectiveness. METHODS: A prospective, patient-blind, randomized, multicenter noninferiority study in 26 French hospitals was conducted. Patients were randomized 1:1 to suturing with conventional thread or a semiautomatic stapler. The Patient Scar Assessment Scale was rated at 3 months for primary endpoint effectiveness. Secondary endpoints were cost-effectiveness of the two suturing methods, prevalence of complications, suturing/operating time, Observer Scar Assessment Scale and Patient Scar Assessment Scale score, scar aesthetic quality 18 months after surgery, and occupational exposure to blood during surgery. RESULTS: Six hundred sixty-four patients were enrolled, 660 were randomized, and 649 constituted the full analysis (stapler arm, n = 324; needle arm, n = 325). Primary endpoint Patient Scar Assessment Scale score in the stapler arm was not inferior to that in the needle arm at 3 months or after 18 months. The mean operating time was 180 minutes in the stapler arm and 179 minutes in the needle arm (p = not significant). The mean suturing time was significantly lower in the stapler arm (p < 0.001). There were seven occupational exposures to blood in the needle arm and one in the stapler arm. The two arms did not differ significantly in terms of complications (p = 0.41). The additional cost of using the device was &OV0556;51.57 for the complete-case population. CONCLUSION: Wound healing outcome was no worse than with conventional suturing using a semiautomatic stapler and associated with less occupational exposure to blood. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, I.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Malard O, Duteille F, Darnis E, et al. A Novel Absorbable Stapler Provides Patient-Reported Outcomes and Cost-Effectiveness Noninferior to Subcuticular Skin Closure: A Prospective, Single-Blind, Randomized Clinical Trial. Plast Reconstr Surg. 2020. PMID: 33234974. doi:10.1097/PRS.0000000000007356