文献速递颅颌面外科

双颌正颌手术中下颌优先与上颌优先及厚薄中间导板的骨骼定位精度

Accuracy of Mandible-First versus Maxilla-First Approach and of Thick versus Thin Splints for Skeletal Position after Two-Jaw Orthognathic Surgery.
PubMed 文献 · Plast Reconstr Surg · 2021-01-01

这项回顾性队列研究纳入57例双颌截骨患者,比较上颌优先(n=31)与下颌优先(n=26)及厚(n=22)、薄(n=35)中间导板对术后骨骼定位精度的影响。术后1周锥形束CT与术前模拟图像重叠测量三维头影标志点偏差,发现两种顺序总体精度无差异,但下颌优先在垂直维度更精确;厚导板对上颌中切牙矢状位置控制更好,但导板厚度不影响总体精度。

要点

  • 下颌优先与上颌优先总体精度无差异,但下颌优先在垂直维度更精确。
  • 厚中间导板对上颌中切牙矢状位置控制优于薄导板。
  • 在合理选择中间导板维持髁突位置的前提下,导板厚度不影响总体精度。

核心结论

  • 两种手术顺序总体精度相似,但下颌优先在垂直维度更精确。
  • 厚中间导板对上颌中切牙矢状位置控制更好,但导板厚度不影响总体精度。

研究设计与样本

  • 回顾性队列研究,纳入57例需双颌截骨的患者。
  • 按手术顺序分为上颌优先组(n=31)和下颌优先组(n=26)。
  • 按中间导板厚度分为厚导板组(n=22)和薄导板组(n=35)。
  • 将术后1周锥形束CT颅面图像与术前模拟图像重叠,测量三维头影标志点偏差。

主要发现

  • 术后1周与术前模拟图像偏差:上颌优先组1.69±0.53 mm,下颌优先组1.44±0.52 mm,总体精度无差异。
  • 下颌优先手术在垂直维度精度更高。
  • 上颌中切牙矢状位置误差:厚导板组1.38±1.17 mm,薄导板组2.13±1.38 mm。
  • 导板厚度对总体精度无影响。
  • 影响顺序选择的因素包括骨性III类伴垂直向过长、上颌向下截骨、颌骨复合体逆时针旋转及模拟下颌张开以制作导板间隙。

临床怎么用

  • 需提高垂直维度精度时可优先选择下颌优先顺序。
  • 需加强上颌中切牙矢状位置控制时可选用厚中间导板。
  • 在合理选择中间导板维持髁突位置的前提下,导板厚度不影响总体精度。

局限性

  • 回顾性队列研究设计。
  • 样本量57例,分组后各组样本量较小。
  • 仅评估术后1周精度,缺乏长期随访。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of this study was to investigate the accuracy of bimaxillary orthognathic surgery regarding different sequencing (maxilla-first or mandible-first surgery) and different thicknesses of intermediate splints. METHODS: This retrospective cohort study evaluated the accuracy of postoperative outcome in accordance with virtual planning in 57 patients requiring bimaxillary osteotomies with different operation sequence: maxilla-first (n = 31) or mandible-first (n = 26) surgery. The effect of different splint thicknesses (i.e., thick, n = 22; and thin, n = 35) was also evaluated. The 1-week postoperative cone-beam computed tomographic craniofacial images were superimposed onto preoperative simulated images to measure the discrepancy of the three-dimensional cephalometric landmarks. RESULTS: Neither sequencing approach differed in overall accuracy (1-week postoperative to preoperative simulated image discrepancy): maxilla-first, 1.69 ± 0.53 mm; versus mandible-first, 1.44 ± 0.52 mm. In detailed comparison, mandible-first surgery resulted in more accuracy in the vertical dimension. Thick intermediate splints provided better control (less error) of upper central incisors in the sagittal position (thick splint, 1.38 ± 1.17 mm; thin splint, 2.13 ± 1.38 mm). However, overall accuracy was not affected by splint thickness. Conditions affecting sequencing predilection included skeletal class III with vertical excess, maxillary down-grafting, counterclockwise rotation of the maxillomandibular complex, and simulated mandibular opening for splint fabrication clearance. CONCLUSIONS: Despite both means of sequencing being performed similarly, mandible-first surgery was more precise in the vertical dimension. Thick intermediate splints seemed to yield better control of central incisors in the sagittal position. However, under appropriate selection of intermediate splints to maintain interim condylar position, splint thickness has no effect on overall accuracy. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, III.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Borikanphanitphaisan T, Lin CH, Chen YA, et al. Accuracy of Mandible-First versus Maxilla-First Approach and of Thick versus Thin Splints for Skeletal Position after Two-Jaw Orthognathic Surgery. Plast Reconstr Surg. 2021. PMID: 33235045. doi:10.1097/PRS.0000000000007536

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。