文献速递显微修复重建创面修复

吲哚菁绿血管造影在大鼠穿支皮瓣模型中预测组织坏死比热成像和近红外光谱更准确

Indocyanine Green Angiography Predicts Tissue Necrosis More Accurately Than Thermal Imaging and Near-Infrared Spectroscopy in a Rat Perforator Flap Model.
PubMed 文献 · Plast Reconstr Surg · 2020-01-01

本研究在大鼠穿支皮瓣模型中比较吲哚菁绿血管造影、热成像和近红外光谱术中预测皮瓣坏死的准确性。结果显示三种技术均能检测灌注差异并预测坏死,但吲哚菁绿血管造影的曲线下面积、敏感度、特异度和准确度最高。

要点

  • 吲哚菁绿血管造影预测皮瓣坏死的准确度最高(92%)。
  • 热成像和近红外光谱也能预测坏死,可作为成本更低或更易获取的替代方案。
  • 三种技术均检测到皮瓣长度方向的灌注显著差异(p < 0.001)。

核心结论

  • 吲哚菁绿血管造影在本研究中预测皮瓣坏死最准确,但组织血氧测定和热成像也能预测坏死,且可能是成本更低或更易获取的客观灌注评估替代方案。

研究设计与样本

  • 在14只体重250 ± 50 g的成年雄性大鼠中掀起10 × 3 cm腹壁上穿支皮瓣,术后第7天以临床皮瓣坏死为金标准终点。

主要发现

  • 三种技术均检测到皮瓣长度方向的灌注显著差异(均p < 0.001),且均与皮瓣坏死 odds 显著差异相关(均p < 0.001)。
  • 受试者工作特征曲线下面积:吲哚菁绿血管造影绝对值0.948,热成像相对变化0.873,组织氧合0.792。
  • 吲哚菁绿血管造影绝对值的敏感度、特异度和准确度最高,分别为97.8%、87.5%和92%。

关键数值与推荐

  • 吲哚菁绿血管造影绝对值:AUC 0.948,敏感度97.8%,特异度87.5%,准确度92%。
  • 热成像相对变化:AUC 0.873。
  • 组织氧合:AUC 0.792。

临床怎么用

  • 临床可优先考虑吲哚菁绿血管造影进行术中皮瓣灌注评估以预测坏死。
  • 热成像和近红外光谱可作为成本更低或更易获取的替代选择。

局限性

  • 研究仅在大鼠穿支皮瓣模型中进行,结论外推至临床需进一步研究。
  • 需额外研究明确各技术在临床实践中的作用和成本效益。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Clinical examination alone is neither sensitive nor specific for predicting flap necrosis, so several technologies, including indocyanine green angiography, thermal imaging (using the FLIR ONE), and near-infrared spectroscopy, have been developed to supplement perfusion assessment. This study aims to compare the accuracy of these three methods for intraoperatively predicting clinical flap necrosis in a rat perforator flap model. The authors hypothesized that near-infrared spectroscopy, assessing oxygenation rather than direct perfusion, would yield significantly different predictions. METHODS: A 10 × 3-cm epigastric perforator flap was elevated in 14 adult male rats weighing 250 ± 50 g. Flap perfusion was assessed immediately after flap elevation using thermal imaging, near-infrared spectroscopy, and indocyanine green angiography. Measurements were correlated to the clinical endpoint and gold standard of flap necrosis on postoperative day 7. RESULTS: All three technologies detected significant differences in perfusion along flap length (all p < 0.001), and were associated with significant differences in the odds of developing flap necrosis (all p < 0.001). The areas under the receiver operating characteristic curves were 0.948 for indocyanine green angiography as an absolute value, 0.873 for relative changes with thermal imaging, and 0.792 for tissue oxygenation. The sensitivity, specificity, and accuracy for indocyanine green angiography measured as an absolute value were the highest at 97.8, 87.5, and 92 percent, respectively. CONCLUSIONS: Indocyanine green angiography most accurately predicted flap necrosis in this study; however, tissue oximetry and thermal imaging were also capable of predicting necrosis and represented potentially less expensive or more readily available alternatives for objective perfusion assessment. Additional research can further delineate their roles and cost-efficacy in clinical practice.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Han T, Khavanin N, Wu J, et al. Indocyanine Green Angiography Predicts Tissue Necrosis More Accurately Than Thermal Imaging and Near-Infrared Spectroscopy in a Rat Perforator Flap Model. Plast Reconstr Surg. 2020. PMID: 33141531. doi:10.1097/PRS.0000000000007278

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。