基于激光技术的烧伤深度循证评估:现状与展望
本文系统综述了基于皮肤微循环测量的非侵入性激光技术(LDF、LDI、LSCI)在烧伤深度评估中的应用。LDI是目前最客观准确的诊断工具,可扫描大面积烧伤区域,准确率达96%,能减少手术次数、改善功能与美学结局并具成本效益,但全球烧伤中心仍未常规使用。LSCI证据有限,尚需技术改进与科学验证。
要点
- LDI是评估烧伤深度与愈合潜能最客观准确的工具,准确率达96%。
- LDI可减少手术次数、改善功能与美学结局,且具成本效益。
- LSCI证据有限,尚需技术改进与科学验证才能可靠用于烧伤评估。
核心结论
- LDI在确定烧伤患者最佳治疗方案方面已证明具有不可估量的价值,但全球烧伤中心仍未常规使用。
- 需要进一步研究以识别普及这一循证烧伤深度评估工具的潜在障碍。
研究设计与样本
- 本文为系统综述,纳入使用皮肤微循环测量的非侵入性激光技术(LDF、LDI、LSCI)评估烧伤深度与愈合时间的研究。
主要发现
- 单点LDF测量的重要缺点包括需直接接触创面床上众多小点以及需数天内进行连续测量。
- LDI是一种快速、非接触的单次测量工具,可扫描大面积烧伤区域,准确率达96%。
- LDI减少手术次数、改善功能与美学结局并具成本效益。
- LSCI用于烧伤深度评估的证据有限,仍需技术改进与科学验证才能被批准用于可靠烧伤评估。
关键数值与推荐
- LDI扫描大面积烧伤区域的准确率为96%。
临床怎么用
- LDI可用于确定烧伤患者的最佳治疗方案,以减少不必要手术并改善长期功能与美学结局。
局限性
- LSCI用于烧伤深度评估的证据有限,尚需技术改进与科学验证。
- LDI虽已证明价值,但全球烧伤中心仍未常规使用的原因尚不明确。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Early clinical assessment of burn depth and associated healing potential (HP) remains extremely challenging, even for experienced surgeons. Inaccurate diagnosis often leads to prolonged healing times and unnecessary surgical procedures, resulting in incremental costs, and unfavorable outcomes. Laser Doppler imaging (LDI) is currently the most objective and accurate diagnostic tool to measure blood flow and its associated HP, the main predictor for a patient's long-term functional and aesthetic outcome. A systematic review was performed on non-invasive, laser-based methods for burn depth assessment using skin microcirculation measurements to determine time to healing: Laser Doppler flowmetry (LDF), LDI and laser speckle contrast imaging (LSCI). Important drawbacks of single point LDF measurements are direct contact with numerous small points on the wound bed and the need to carry out serial measurements over several days. LDI is a fast, "non-contact," single measurement tool allowing to scan large burned areas with a 96% accuracy. LDI reduces the number of surgeries, improves the functional and aesthetic outcome and is cost-effective. There is only limited evidence for the use of LSCI in burn depth assessment. LSCI still needs technical improvements and scientific validation, before it can be approved for reliable burn assessment. LDI has proven to be invaluable in determining the optimal treatment of a burn patient. For unclear reasons, LDI is still not routinely used in burn centers worldwide. Additional research is required to identify potential "barriers" for universal implementation of this evidence-based burn depth assessment tool.
引用
- Claes KEY, Hoeksema H, Vyncke T, et al. Evidence Based Burn Depth Assessment Using Laser-Based Technologies: Where Do We Stand? J Burn Care Res. 2021. PMID: 33128377. doi:10.1093/jbcr/iraa195
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。