文献速递烧伤创面修复

拉曼光谱在离体模型中准确分类烧伤严重程度

Raman spectroscopy accurately classifies burn severity in an ex vivo model.
PubMed 文献 · Burns · 2020-08-31

本研究在离体猪皮肤上设计四种烧伤条件(200°F或450°F分别持续10秒或30秒)及未烧伤对照,采集500-2000cm⁻¹拉曼光谱,用PCA+KSVM和PLS两种方法分类,两种技术平均准确率均约92%,经留一交叉验证独立评估。PCA+KSVM对重度烧伤分类更优,PLS对轻度烧伤更优。

要点

  • 拉曼光谱单独即可对离体猪皮肤烧伤程度进行分类,平均准确率约92%。
  • PCA+KSVM在重度烧伤(450°F)分类中准确率更高,PLS在轻度烧伤(200°F)中表现更好。
  • PLS模型VIP评分显示蛋白质/脂质、酰胺III和氨基酸是区分未烧伤或轻度烧伤的重要指标,酰胺I对区分重度烧伤影响更明显。

核心结论

  • 拉曼光谱单独使用在离体猪皮肤模型中分类烧伤严重程度的平均准确率约92%,经留一交叉验证评估。
  • PCA+KSVM与PLS两种分类方法平均准确率均约92%,但PCA+KSVM在重度烧伤分类中准确率更高,PLS在轻度烧伤分类中表现更好。

研究设计与样本

  • 离体猪皮肤组织实验,设计四种烧伤条件:200°F持续10秒、200°F持续30秒、450°F持续10秒、450°F持续30秒,并设未烧伤对照。
  • 采集500-2000cm⁻¹拉曼光谱,采用PCA提取特征后结合KSVM分类,以及PLS分类,通过留一交叉验证(LOOCV)独立评估。

主要发现

  • PCA+KSVM和PLS两种技术平均准确率均约92%,经LOOCV独立评估。
  • PCA+KSVM在重度烧伤(450°F)分类中准确率高于PLS,PLS在轻度烧伤(200°F)分类中表现更好。
  • PLS模型VIP评分显示蛋白质和脂质、酰胺III、氨基酸是区分未烧伤或轻度烧伤(200°F)的重要指标,酰胺I对区分重度烧伤(450°F)影响更明显。

临床怎么用

  • 拉曼光谱单独使用有望作为烧伤严重程度分类的辅助工具,但当前仅为离体猪皮肤模型结果,尚未进入临床。
  • 针对不同烧伤程度可选择不同分类算法:重度烧伤倾向PCA+KSVM,轻度烧伤倾向PLS。

局限性

  • 研究为离体猪皮肤组织实验,非在体人类临床研究,结论外推需谨慎。
  • 样本仅涉及四种特定温度与时间组合的烧伤条件,未覆盖其他烧伤参数。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Accurate classification of burn severities is of vital importance for proper burn treatments. A recent article reported that using the combination of Raman spectroscopy and optical coherence tomography (OCT) classifies different degrees of burns with an overall accuracy of 85% [1]. In this study, we demonstrate the feasibility of using Raman spectroscopy alone to classify burn severities on ex vivo porcine skin tissues. To create different levels of burns, four burn conditions were designed: (i) 200°F for 10s, (ii) 200°F for 30s, (iii) 450°F for 10s and (iv) 450°F for 30s. Raman spectra from 500-2000cm-1 were collected from samples of the four burn conditions as well as the unburnt condition. Classifications were performed using kernel support vector machine (KSVM) with features extracted from the spectra by principal component analysis (PCA), and partial least-square (PLS). Both techniques yielded an average accuracy of approximately 92%, which was independently evaluated by leave-one-out cross-validation (LOOCV). By comparison, PCA+KSVM provides higher accuracy in classifying severe burns, while PLS performs better in classifying mild burns. Variable importance in the projection (VIP) scores from the PLS models reveal that proteins and lipids, amide III, and amino acids are important indicators in separating unburnt or mild burns (200°F), while amide I has a more pronounced impact in separating severe burns (450°F).

来源:Burns,查看原文。版权归原作者所有。

引用

  1. Ye H, Rahul, Kruger U, et al. Raman spectroscopy accurately classifies burn severity in an ex vivo model. Burns. 2020. PMID: 32928613. doi:10.1016/j.burns.2020.08.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。