贝克分类用于乳房植入物包膜挛缩的诊断不可靠
结果显示贝克分类的观察者间信度差(kappa 0.55,95%CI 0.37–0.72),观察者间一致性仅48%,提示需要更可靠的测量或描述方法。
要点
- 贝克分类的观察者间信度差(kappa 0.55,95%CI 0.37–0.72)。
- 观察者间一致性仅48%,43%的病例相差一个等级,12%相差超过一个等级。
- 硬结、移位、对称性的信度也差,疼痛评分信度较好但多数患者无痛。
核心结论
- 贝克分类用于包膜挛缩的观察者间信度和一致性差,缺乏对症状评级的共识,需要更可靠的测量或描述方法。
主要发现
- 贝克分类的观察者间信度差(kappa 0.55,95%CI 0.37–0.72)。
- 硬结(0.64,95%CI 0.49–0.79)、移位(0.49,95%CI 0.26–0.73)、对称性(0.61,95%CI 0.34–0.88)的信度也差。
- 疼痛评分信度较好(0.72,95%CI 0.56–0.89),但多数患者无痛。
- 贝克评分的观察者间一致性为48%,43%的病例相差一个等级,12%相差超过一个等级。
临床怎么用
- 在临床和科研中应谨慎依赖贝克分类评估包膜挛缩,需探索更可靠的测量或描述方法。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Breast implants are frequently used in cosmetic and reconstructive breast surgery. Capsular contracture, the most common long-term complication, is usually graded using the Baker classification. Despite its widespread use, the reliability of the Baker classification has never been established. The aim of this study was to determine the interobserver reliability and agreement of the Baker classification. METHODS: Sixty women who had undergone cosmetic breast augmentation were included. They were examined independently by two plastic surgeons from an observer pool. The Baker score was determined, along with firmness, dislocation, symmetry, and pain using four-point scales. Patients were asked to complete the BREAST-Q postaugmentation module. The interobserver reliability and agreement were calculated for all variables with a quadratic weighted kappa. RESULTS: The interobserver reliability of the Baker classification was poor (kappa, 0.55; 95 percent CI, 0.37 to 0.72). Interobserver reliability of the clinical parameters firmness (0.64; 95 percent CI, 0.49 to 0.79), dislocation (0.49; 95 percent CI, 0.26 to 0.73), and symmetry (0.61; 95 percent CI, 0.34 to 0.88) was also poor. Pain scores seemed more reliable (0.72; 95 percent CI, 0.56 to 0.89); however, most patients had no pain. The interobserver agreement for the Baker score was 48 percent; in 43 percent, the observers differed one category; and in 12 percent, the difference was more than one category. CONCLUSIONS: Interobserver reliability and observer agreement of the Baker classification for capsular contracture were poor. Consensus about how to adequately rate the symptoms of capsular complaints is lacking. A more reliable method of measurement or description is needed, especially for scientific research purposes, to assess the long-term problems associated with breast implants. CLINICAL QUESTION/LEVEL OF EVIDENCE: Diagnostic, IV.
引用
- de Bakker E, Rots M, Buncamper ME, et al. The Baker Classification for Capsular Contracture in Breast Implant Surgery Is Unreliable as a Diagnostic Tool. Plast Reconstr Surg. 2020. PMID: 32852468. doi:10.1097/PRS.0000000000007238
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。