文献速递乳房整形与再造美容整形

Telfa滚动法与封闭冲洗系统在乳房切除术后自体脂肪移植中的比较

Comparison of Telfa Rolling and a Closed Washing System for Autologous Fat Processing Techniques in Postmastectomy Breast Reconstruction.
PubMed 文献 · Plast Reconstr Surg · 2020-01-01

本研究回顾性比较了Telfa滚动法与封闭冲洗系统在乳房切除术后乳房重建患者脂肪移植中的应用。共纳入186例女性、319次脂肪移植操作。结果显示封闭冲洗系统组影像学确认的脂肪坏死率显著低于Telfa滚动法组(8.0% vs 20.6%,p<0.01),且封闭冲洗系统是影像学确认脂肪坏死率降低的独立预测因素(OR 0.29,p=0.048)。

要点

  • 封闭冲洗系统组影像学确认脂肪坏死率显著低于Telfa滚动法组(8.0% vs 20.6%,p<0.01)。
  • Telfa滚动法组可触及肿块需影像学检查的比例更高(26.0% vs 14.4%,p=0.01)。
  • 封闭冲洗系统是影像学确认脂肪坏死率降低的独立预测因素(OR 0.29,p=0.048)。

核心结论

  • 封闭冲洗系统与Telfa滚动法相比,影像学确认的脂肪坏死率降低,且不增加其他并发症。

研究设计与样本

  • 回顾性队列研究,纳入2013年1月至2017年9月间186例女性共319次脂肪移植操作,按技术分组,排除随访不足180天者。

主要发现

  • 两组人口学特征、手术次数、移植脂肪体积及重建后至脂肪移植的天数无差异(p>0.05)。
  • Telfa滚动法组第二次脂肪移植手术时间更长(100.0分钟 vs 79.0分钟,p=0.03)。
  • Telfa滚动法组可触及肿块需影像学检查的比例更高(26.0% vs 14.4%,p=0.01)。
  • Telfa滚动法组脂肪坏死发生率更高(20.6% vs 8.0%,p<0.01)。
  • 封闭冲洗系统是影像学确认脂肪坏死率降低的独立预测因素(OR 0.29,p=0.048)。

关键数值与推荐

  • 影像学确认脂肪坏死率:封闭冲洗系统组8.0%,Telfa滚动法组20.6%(p<0.01)。
  • 可触及肿块需影像学检查比例:封闭冲洗系统组14.4%,Telfa滚动法组26.0%(p=0.01)。
  • 第二次脂肪移植手术时间:Telfa滚动法组100.0分钟(范围60.0-150.0),封闭冲洗系统组79.0分钟(范围64.0-94.0),p=0.03。
  • 封闭冲洗系统预测影像学确认脂肪坏死的OR为0.29(p=0.048)。

临床怎么用

  • 在乳房切除术后自体脂肪移植中,可优先考虑封闭冲洗系统以降低影像学确认的脂肪坏死率。
  • Telfa滚动法组可触及肿块需影像学检查的比例更高,术后需注意肿块鉴别。

局限性

  • 回顾性研究设计,证据等级为治疗性III级。
  • 随访不足180天的患者被排除,可能影响并发症评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The purpose of this study was to compare the commonly used fat grafting techniques-Telfa rolling and a closed washing system-in breast reconstruction patients. METHODS: Consecutive patients undergoing fat grafting were retrospectively reviewed and grouped by technique. Patients with less than 180 days of follow-up were excluded. Demographics, operative details, and complications were compared using univariate analysis with significance set at p < 0.05. RESULTS: Between January of 2013 and September of 2017, 186 women underwent a total of 319 fat grafting procedures. There was no difference in demographics, number of procedures performed, volume of fat grafted, and number of days after reconstruction that fat grafting was performed between groups (p > 0.05). Telfa rolling patients had longer operative times for second fat grafting procedures (implant exchange often completed prior) [100.0 minutes (range, 60.0 to 150.0 minutes) versus 79.0 minutes (range, 64.0 to 94.0 minutes); p = 0.03]. Telfa rolling breasts had more palpable masses requiring imaging (26.0 percent versus 14.4 percent; p = 0.01) and an increased incidence of fat necrosis (20.6 percent versus 8.0 percent; p < 0.01). The closed washing system was found to be an independent predictor of decreased rates of imaging-confirmed fat necrosis (OR, 0.29; p = 0.048). There was no difference in fat necrosis excision or cancer recurrence between the groups. CONCLUSION: The closed washing system was independently associated with decreased rates of imaging-confirmed fat necrosis compared to Telfa rolling without an increase in other complications. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, III.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Valmadrid AC, Kaoutzanis C, Wormer BA, et al. Comparison of Telfa Rolling and a Closed Washing System for Autologous Fat Processing Techniques in Postmastectomy Breast Reconstruction. Plast Reconstr Surg. 2020. PMID: 32842097. doi:10.1097/PRS.0000000000007053

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。