游离皮瓣术前血管规划:CTA、彩色多普勒超声与手持多普勒的比较研究
彩色多普勒超声的敏感性、特异性和准确率均高于CTA和手持多普勒,且与手术发现100%一致。
要点
- 彩色多普勒超声检测穿支与手术发现完全一致。
- 彩色多普勒超声可清晰显示直径小于0.5mm的血管。
- 手持多普勒阳性预测值88.6%,阴性预测值90.5%。
核心结论
- 彩色多普勒超声提供可重复、无害且准确的血管解剖可视化方法。
- 彩色多普勒超声的敏感性、特异性和准确率优于手持多普勒和CTA。
研究设计与样本
- 每例患者术前均用三种方法检测穿支,并与术中结果比较。
主要发现
- 71.7%的重建使用股前外侧皮瓣。
- 阳性预测值:彩色多普勒超声100%,CTA 100%,手持多普勒88.6%。
- 阴性预测值:彩色多普勒超声100%,CTA 94.3%,手持多普勒90.5%。
- 彩色多普勒超声检测的穿支与手术发现100%一致。
关键数值与推荐
- 彩色多普勒超声可有效检测直径小于0.5mm的血管。
- 证据水平:诊断性研究,II级。
临床怎么用
- 术前可优先选用彩色多普勒超声进行穿支定位和血管规划。
- 彩色多普勒超声结果与术中高度一致,有助于提高手术规划准确性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Preoperative planning of microsurgical perforator free flaps continues to be a discussion topic among microsurgeons. The purpose of this study was to compare the ability of three methods of preoperative vascular mapping-hand-held Doppler imaging, color Doppler ultrasonography, and computed tomographic angiography-to detect perforators and their concordance with surgical findings. METHODS: A prospective study was performed to evaluate the sensitivity, specificity, and accuracy of hand-held Doppler imaging, color Doppler ultrasonography, and computed tomographic angiography to detect free flap perforators. Each patient undergoing a free flap reconstruction was studied preoperatively with the three methods, and the results were compared to the intraoperative findings. RESULTS: Fifty-three patients undergoing autologous tissue reconstruction were included. Most reconstructions (71.7 percent) were performed with anterolateral thigh flaps. The positive predictive value (color Doppler ultrasonography, 100 percent; computed tomographic angiography, 100 percent; hand-held Doppler imaging, 88.6 percent) and negative predictive value (color Doppler ultrasonography, 100 percent; computed tomographic angiography, 94.3 percent; hand-held Doppler imaging, 90.5 percent) rates were significantly different between methods. The high resolution of the color Doppler ultrasonography probe provided a direct vision of the vasculature arborization and efficiently detected vessels with diameters of less than 0.5 mm. The sensitivity, specificity, and accuracy of color Doppler ultrasonography were greater than those of both computed tomographic angiography and hand-held Doppler imaging. There was 100 percent concordance between color Doppler ultrasonography perforators and the surgical findings. CONCLUSIONS: Color Doppler ultrasonography provides a reproducible, harmless, and accurate way to visualize vascular anatomy. It has a high correlation with the surgical findings, signifying advantages over hand-held Doppler and computed tomographic angiography in sensitivity, specificity, and accuracy. CLINICAL QUESTION/LEVEL OF EVIDENCE: Diagnostic, II.
引用
- González Martínez J, Torres Pérez A, Gijón Vega M, et al. Preoperative Vascular Planning of Free Flaps: Comparative Study of Computed Tomographic Angiography, Color Doppler Ultrasonography, and Hand-Held Doppler. Plast Reconstr Surg. 2020. PMID: 32740566. doi:10.1097/PRS.0000000000006966
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。