文献速递乳房整形与再造

Vectra三维成像系统预测乳房质量是否可靠?

Is the Vectra 3D Imaging System a Reliable Tool for Predicting Breast Mass?
PubMed 文献 · Ann Plast Surg · 2020-01-01

本研究回顾性分析2015年2月至2019年2月由单一术者完成的202侧乳房直接置入假体再造,评估Vectra三维成像系统预测乳房质量(VPM)与乳房切除标本质量(MM)的相关性。结果显示两者强相关(R=0.90,P<0.0001),推导公式MM=0.8×VPM+32(校正r=0.81),但VPM在不同罩杯间差异显著(P<0.0001),假性下垂乳房中相关性显著降低(0.90 vs 0.75,P=0.0425)。

要点

  • Vectra预测质量与标本质量强相关(R=0.90),可用于术前规划参考。
  • VPM在不同罩杯大小间差异显著,预测可靠性随罩杯变化。
  • 假性下垂乳房中VPM与MM相关性显著降低,需谨慎解读。

核心结论

  • Vectra预测乳房质量的可靠性随罩杯大小变化,假性下垂乳房中VPM与MM关联显著降低。

研究设计与样本

  • 回顾性 review,纳入2015年2月至2019年2月单一术者完成的202侧直接置入假体再造乳房。

主要发现

  • MM与VPM强相关(R=0.90,P<0.0001),推导公式MM=0.8×VPM+32(校正r=0.81)。
  • Bartlett检验显示VPM在不同罩杯间差异显著(P<0.0001)。
  • 假性下垂乳房中VPM与MM相关系数显著降低(0.90 vs 0.75,P=0.0425)。

关键数值与推荐

  • 罩杯近似标准:A及更小(MM≤250 g),B(250 g<MM≤450 g),C(450 g<MM≤600 g),D及更大(MM≥600 g)。
  • BMI分类:偏瘦(BMI<20 kg/m),正常(20 kg/m≤BMI<25 kg/m),超重(25 kg/m≤BMI<30 kg/m),肥胖(BMI≥30 kg/m)。
  • 显著性设定α=0.05,分析使用R 3.6.0版本1.70。

临床怎么用

  • 使用Vectra预测乳房质量时需考虑罩杯大小对准确性的影响。
  • 对假性下垂乳房,VPM与MM相关性降低,术前规划应谨慎依赖该预测值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In selecting breast implants for breast reconstruction, current preoperative planning largely relies on 2-dimensional measurements, which are often limited in suboptimal accuracy and objectivity. Although the introduction of 3-dimensional imaging modalities has further improved preoperative planning, they require in-depth analysis of accuracy if they are to be considered as a standardized part of preoperative planning. Thus, the present study analyzes the reliability of the Vectra 3D Imaging System in predicting breast mass and explores potential confounding variables that may limit its accuracy. METHODS: A retrospective review of 202 breasts that received direct-to-implant reconstruction by a single surgeon between February 2015 and February 2019 was conducted. Variables recorded included Vectra predicted mass (VPM; in grams), mastectomy mass (MM; in grams), ptosis grade, and body mass index (BMI). Body mass index was classified as follows: underweight (BMI < 20 kg/m), normal (20 kg/m ≤ BMI < 25 kg/m), overweight (25 kg/m ≤ BMI < 30 kg/m), and obese (BMI ≥ 30 kg/m). Cup size was approximated as follows: A and smaller (MM ≤250 g), B (250 g < MM ≤ 450 g), C (450 g < MM ≤ 600 g), and D and larger (MM ≥ 600 g). Correlation between MM and VPM was evaluated using 2-tailed Pearson correlation coefficients (r), and associated formula was derived from a linear model. Equality of variances was assessed with the Bartlett test. Correlation coefficients calculated for ptosis and BMI categories were then compared with the overall correlation coefficient. Significance was set at α = 0.05, and analyses were conducted in R 3.6.0, version 1.70. RESULTS: There was a strong correlation between MM and VPM (R = 0.90, P < 0.0001). The following equation was derived to predict MM: [MM] = 0.8 × [VPM] + 32 (adjusted r = 0.81). The Bartlett test indicated that VPM varies significantly across cup sizes (P < 0.0001). Comparison of correlation coefficients for ptosis and BMI categories revealed a significantly reduced correlation coefficient for pseudoptosis (0.90 vs 0.75, P = 0.0425). CONCLUSIONS: The present study suggests that the reliability of Vectra in predicting breast mass varies across cup sizes and that there exists a significantly decreased association between VPM and MM among pseudoptotic breasts. These are important considerations when using this technology in surgical planning.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Wood KL, Zoghbi Y, Margulies IG, et al. Is the Vectra 3D Imaging System a Reliable Tool for Predicting Breast Mass? Ann Plast Surg. 2020. PMID: 32539287. doi:10.1097/SAP.0000000000002333

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。