文献速递乳房整形与再造

马源性脱细胞心包基质(APM)用于乳房重建的可行性研究

Feasibility study on equine acellular pericardium matrix (APM): A new tool for breast reconstruction.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2020-05-19

本研究首次描述一种新型马源性脱细胞心包基质(Equity APM)在假体乳房重建中的应用并评估其安全性。

要点

  • 马源性APM用于假体乳房重建并发症率可接受,患者满意度高。
  • 常见并发症包括上极可见(9.5%)、血清肿(1.6%)及裂开、感染、坏死各3.2%。
  • 假体丢失率3.2%,提示APM安全性可接受。

核心结论

  • 马源性APM用于假体乳房重建并发症率可接受、美学效果满意,可视为较厚且昂贵ADM的可行替代。

主要发现

  • 重建乳房为小至中等,假体平均重量285 g(范围145–685 g)。
  • 2例既往放疗,7例术后放疗;5例活跃吸烟,6例高血压。
  • 并发症:上极可见9.5%、血清肿1.6%、裂开3.2%、感染3.2%、坏死3.2%,假体丢失3.2%。
  • 患者高度满意,Breast-Q问卷各 section 评分均>50。

临床怎么用

  • 马源性APM可用于小至中等乳房假体再造的下极覆盖,需注意上极可见、血清肿及感染等并发症。

局限性

  • 回顾性研究性质限制其临床影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The advent of acellular dermal matrix (ADM) for lower pole coverage allows immediate reconstructions with improved aesthetic outcomes and faster recovery. This study describes for the first time, the use of a new acellular pericardium matrix (APM) in implant-based breast reconstruction and characterises its safety profile. Equity is a membrane with a natural cross-linked structure with many of the properties of ADMs, but improved resistance and reduced thickness. A retrospective data collection of all Equity APM reconstructions was conducted at two Italian hospital centres with substantial experience using biomaterials. Between May 2013 and October 2018, a total of 63 APM-assisted breast reconstructions were performed in 55 women. The reconstructed breasts were small to medium and the mean implant weight was 285 g, ranging from 145 g to 685 g. Two patients were previously irradiated while seven received post-operative radiation; five were active smokers and six were hypertensive. Complications included visibility in the upper pole (9.5%), seroma (1.6%), dehiscence, infection and necrosis (3.2% for each). Implant loss occurred in 3.2% of the cases. The patients were highly satisfied, reporting scores above 50 for each section of the Breast-Q questionnaire. With an acceptable complication rate, the use of the equine APM can be considered safe with satisfactory aesthetic results. Although the retrospective nature of this study limits its clinical impact, the use of Equity can be considered a viable alternative to thicker and expensive ADMs.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Berna G, Cagli B, Persichetti P, et al. Feasibility study on equine acellular pericardium matrix (APM): A new tool for breast reconstruction. J Plast Reconstr Aesthet Surg. 2020. PMID: 32513644. doi:10.1016/j.bjps.2020.05.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。